DANLERS CEFL PIR Installation Notes Download Page 1

DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.

Telephone: +44 (0)1249 443377   Fax: +44 (0)1249 443388   

E-mail: [email protected]    Web: 

www.danlers.co.uk

Company Registered Number 2570169   VAT Registration Number 543 5491 38

Products available from DANLERS

•  PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers 
•  Photocells  •  Radio  remote  controls  • Time  lag  switches  •  Outdoor  security  switches 
•  Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. products

Please call for more information or a free catalogue, or visit our website.

This product conforms to BS EN 60669-2-1.
Please ensure the most recent edition of the appropriate local wiring regulations are observed 
and suitable protection is provided e.g. 6 amps over current, 1kV over voltage. Please ensure 
that this device is disconnected from the supply if an insulation test is made. 
This product is covered by a warranty which extends to 5 years from the date of manufacture.

Precautions and Warranty 

Installation notes

  Ceiling flush PIR occupancy switches 

  CEFL PIR 

CEFLP PIR 

  CEFL PIR 10A 

CEFL PIR SEALED

DANLERS ceiling flush passive infra-red occupancy switches (PIR) can 
be flush mounted into suspended and plasterboard ceilings (diagram 
A). They include a 2 metre connecting flex to make installation quicker 
and easier.
These PIR switches incorporate a passive infra-red quad sensor to 
detect movement of a warm body within their detection zone (diagram 
B) and a photocell to monitor the ambient light level.
Upon detecting movement, if the ambient light is dark enough, the 
PIR switch will turn the load on. The ambient threshold can be set by 
the user to between approximately 100 lux and infinite lux (photocell 
inactive) via the LUX adjuster (diagram E).
If no more movement is detected within a pre-selected time, then 
the PIR switch will turn the load off. This time lag can be set via the 
TIME adjuster to 10 seconds, 20s, 40s, 1 minute 15 seconds, 2m30s, 
5m, 10m, 20m or 40 minutes (diagram E).

CEFL PIR variants

CEFL PIR 

Standard flush mounted PIR switch 

CEFLP PIR 

Includes a Klik-AX plug. 

CEFL PIR 10A 

Up-rated to switch 10A resistive loads. 

CEFL PIR SEALED 

Suitable for bathrooms, zones 2 and 3.

Loading

These PIR switches can switch up to 6 amps 

 (1500W) of: 

•  Fluorescent lamps, high frequency or switch start 
•  Incandescent or mains halogen lamps

 (recommended with integral safety fuse) 

•  Electronic or wire wound transformers.

 The CEFL PIR 10A can switch up to 10 amps (2500W) of the above loads.

They can also switch up to: 

•  1 amp (250W) of fans or most metal halide lamps.

05/10/11

INS942 CEFL PIR

Variants

As DANLERS design and manufacture in the UK, variants can be supplied, 

coded by the following suffixes and applied in this order:
•  12V or 24V   

12V or 24V (ac or dc) operation 

•  VF 

 

 

Volt Free contacts 

•  GOLD or LG 

Gold or Logic Gold contacts 

•  NC 

 

 

Normally Closed contacts 

•  3M 

 

 

3 Metre (or other) length flex

Variant details are covered in an enclosed addendum sheet if applicable.

Troubleshooting

 

The load will not switch on:

 

•  The LUX adjuster is set too low and is inhibiting the switch. 

•  The moving body is not emitting more IR than the background. 

    (Person wearing insulating clothing in a warm environment) 

•  Person is too far from the PIR switch, see detection diagram. 

•  Person is moving unusually slowly (perhaps when testing).

The load switches on when nobody is present:

 

•  Heater causing infra-red variations in a small cold room. 

    Consider using the CEFL PIR 2DRS, double detection version. 

•  Ceiling void drafts or opening sealed doors causing air movement. 

    Consider using the CEFL PIR XS2D, extra sealed version. 

•  Please contact DANLERS for further technical support.  

   

Summary of Contents for CEFL PIR

Page 1: ...inactive via the LUX adjuster diagram E If no more movement is detected within a pre selected time then the PIR switch will turn the load off This time lag can be set via the TIME adjuster to 10 secon...

Page 2: ...if the wall switch is placed after the PIR diagrams C E note 2 it will not enter the start up mode each time Time and Lux set up For convenience ensure that the TIME is set to the minimum when settin...

Page 3: ...rolZAPP icon should now appear in your Applications folder Repeat the process to download the ControlZAPP GC Widget red icon Save will transfer the file to your downloads folder Clicking on the downlo...

Page 4: ...orted onto other devices Press Profile button then select the profile to be shared Press Share bottom left New screen appears with all of the programs your mobile tablet could share with These program...

Page 5: ...nd user to occupy an area for a short period of time without the ControlZAPP enabled PIR holding a connected load ON for its full Turn OFF Timeout providing the area is occupied for less time than hal...

Page 6: ...fore the ControlZAPP control will switch a connected load OFF after the photocell senses that sufficient natural light is available This avoids unnecessary switching due to passing clouds To alter Del...

Page 7: ...ering the timer to the desired setting To set Offset from Sunrise press Sunrise button Press timer 0 to reveal 24 hour rolling clock sweep up or down to allocate correct start time between the blue li...

Page 8: ...the WEEKLY SCHEDULE screen Repeat for any other days of the week you wish to change Schedule Exceptions Defines exceptions to your Schedule eg Special events Bank Holidays See diagram 22 Launch App t...

Page 9: ...is selected Configure Device Options There are several options only available when connected by Bluetooth Smart to the ControlZAPP device To connect with a ControlZAPP enabled device ensure Bluetooth...

Page 10: ...lighting load will switch ON If the control light level is too low not enough natural light a red warning box is shown warning you to resite the device where it is seeing more natural daylight recalib...

Page 11: ...the device clock battery must be activated by clicking the red dip switch into the down position on the controlzapp device see product instructions Press Clock New screen appears with the clock time...

Page 12: ...ct as approprate When a recipient opens and saves the file it will then have to be opened from the downloads folder on your mobile tablet ControlZAPP app will be launched if installed with a prompt Im...

Page 13: ...hat the most recent edition of the appropriate local wiring regulations has been observed and that appropriate protective measures have been applied DANLERS Limited has a policy of continuous developm...

Page 14: ...tooth low energy REPEAT PROCESS IF ADDITIONAL HARDWARE REQUIRES DIFFERENT PROFILES assign device settings inc setup calibration ballast type CLOCK ETC connected via bluetooth SMART IMPORTANT dEVICE CL...