4.5.4.2 Configuring OPC UA Settings
e7
7h
a8
13
.1
0
Procedure
Connect to the web server and click
Configuration
.
Select
OPC UA Server
.
Tick the
Enable
checkbox to enable OPC UA client operation.
The OPC UA client is enabled by default.
Click
Server Configuration
and configure the settings as required.
Select
Actions
to select the actions for different object instances.
Click
Submit
to save all settings in the card.
4.6 Scanning the Network
If there is no connection to the web server and the soft starter cannot be accessed physically, use the Ethernet Device Configuration
Tool to scan the network and identify the device. Changes made via the Ethernet Device Configuration Tool cannot be stored per-
manently in the device and will be lost when the control power is cycled.
Download the Ethernet Device Configuration Tool from
under the sections Services/PC-tools.
N O T I C E
If the PC has a firewall enabled, add the tool to the list of authorized programs.
4.6.1 Identifying the Device with Ethernet Device Configuration Tool
Procedure
Start the Ethernet Device Configuration Tool.
Click
Search Devices
.
AN353423548483en-000101 / 130R0945
14 | Danfoss A/S © 2020.12
Device Configuration
EtherNet/IP Card
Installation Guide