1.
2.
3.
-
-
-
-
8.7 Decommissioning
W A R N I N G
HIGH VOLTAGE
High voltage, which can lead to death or serious injury, is present on the connectors.
Before working on the power connectors (disconnecting or connecting the cable to the VLT® OneGearDrive®), disconnect the
power supply to the drive and wait for the discharge time to elapse (see the drive Operating Guide).
Installation, start-up, maintenance, and decommissioning must only be performed by qualified personnel.
N O T I C E
DANGER OF BURNS
The surface of the VLT® OneGearDrive® and the oil in the VLT® OneGearDrive® can reach high temperatures during operation.
Do not touch the VLT® OneGearDrive® until it has cooled down.
Do not carry out an oil change until the oil has cooled sufficiently.
8.7.1 Dismounting
Procedure
Disconnect the supply to the drive and wait for the discharge time to elapse (see the drive Operating Guide).
Remove the electrical cable from the drive to the VLT® OneGearDrive®.
Dismount the VLT® OneGearDrive®.
8.7.2 Product Returns
Danfoss products can be returned for disposal at no charge. A prerequisite for this is that they are free of deposits, such as oil,
grease, or other types of contamination that hampers disposal. Furthermore, foreign materials or third-party components cannot be
included with the returned product. Ship the products free on board to the local Danfoss sales company.
8.8 Disposal
Do not dispose of equipment containing electrical components together with domestic waste. Collect it separately in accordance
with local and currently valid legislation.
AQ347551551757en-000101 / 130R0239
28 | Danfoss A/S © 2020.12
Maintenance, Decommissioning,
and Disposal
VLT® OneGearDrive®
Operating Guide
Summary of Contents for VLT OneGearDrive
Page 1: ...Operating Guide VLT OneGearDrive drives danfoss com...
Page 2: ......