Definition
Unit
Power size 1
Power size 2
Output
Output voltage
V DC
V
OUT
PSM
Output current DC-link
A DC
15
25
Peak current DC-link (rms value) t <1.0 s
A
rms
30 for <1 s
48 for <1 s
Output current U
AUX
A DC
15
Protective measures
–
Overload, short-circuit, and ground fault protection
Cooling
–
Natural convection
Mounting
–
Wall-mounted on backplate using backlink connector
Weight
kg
3.05
Dimensions (W x H x D)
mm
84.3 x 467.9 x 270
11.4.3 Hybrid Cable Protection
The AUX 24/48 V has 3 levels of protection:
•
Software (seconds timing range): The control boards opens the 24/48 V AUX if an overload is present (>15 A).
•
Hardware (microseconds timing range): Opens automatically if a short circuit of >36 A is present.
•
Hardware: A 20 A non-replaceable SMD (surface-mounted device) fuse in case the first 2 fuses fail.
Specifications
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 211
Danfoss A/S © 2019.10
Summary of Contents for VLT MSD 510