Definition
Unit
Power size 1
Power size 2
Power size 3
Rated power P
N
kW
10
20
30
Peak power P
max
t <3.0 s)
kW
20
40
60
Internal brake resistor
(1)
Peak power P
max
kW
8
Rated power P
N
W
150
Nominal resistance
Ω
15
External brake resistor
Peak power P
max
kW
60
Rated power P
N
kW
7.5
Minimum resistance
Ω
10
General
Line filter in accordance with EN 61800-3
–
Category C3
Cooling
–
Integrated fan
Mounting
–
Wall-mounted on backplate using backlink connector
Weight
kg
6
Dimensions (W x H x D)
mm
137.3 x 406.3 x 270
1
An external brake resistor can be connected.
11.3 Servo Drive Module (SDM 511/SDM 512)
11.3.1 Motor Overload Protection
NOTICE
-
Internal motor overload protection operates at 105% of the motor full load current.
-
Instruct SDM 511/SDM 512 with nominal motor current (full load current according to the motor technical label) to use the
protection properly.
SDM 511/SDM 512 incorporates internal overload protection in the following multiples of current setting:
Table 122: Multiples of Current Setting
Multiple of current setting
Maximum trip time
7.2
20 s
1.5
8 min
1.2
2 hrs