9-64 Device Identification
Range:
Function:
Index
Content
Value
0
Manufacturer
128
1
Device type
1
2
Version
xxyy
3
Firmware date year yyyy
4
Firmware date
month
ddmm
5
No. of axes
Variable
6
Vendor specific: PB
Version
xxyy
7
Vendor specific:
Database Version
xxyy
8
Vendor specific:
AOC Version
xxyy
9
Vendor specific:
MOC Version
xxyy
9-65 Profile Number
Range:
Function:
0
*
[0 - 0 ]
NOTICE
This parameter is not visible via LCP.
This parameter contains the profile identification.
Byte 1 contains the profile number and byte 2 the
version number of the profile.
9-67 Control Word 1
Range:
Function:
0
*
[0 - 65535 ] This parameter accepts the control word from a
master class 2 in the same format as PCD 1.
9-68 Status Word 1
Range:
Function:
0
*
[0 - 65535 ] This parameter delivers the status word for a
master class 2 in the same format as PCD 2.
9-70 Edit Set-up
Select the set-up in which programming (change of data) is
performed during operation. It is possible to program the 4 set-
ups independently of the set-up selected as active. Parameter
access from each master is directed to the set-up, which is
selected by the individual master (cyclic, acyclic MCL1, 1st acyclic
MCL2, 2nd acyclic MCL2, 3rd acyclic MCL2).
Option:
Function:
[1]
Set-up 1
[2]
Set-up 2
[3]
Set-up 3
[4]
Set-up 4
[9]
*
Active Set-up
9-71 Profibus Save Data Values
Option:
Function:
Parameter values changed via RS485 are not
automatically stored in a non-volatile memory.
Use this parameter to activate a function that
stores parameter values in the EEPROM non-
volatile memory, so changed parameter values
are retained at power-down.
[0]
*
Off
Deactivates the non-volatile storage function.
[1]
Store all
setups
Stores all parameter values in the set-up selected
in
parameter 9-70 Edit Set-up
in the non-volatile
memory. The selection returns to
[0] Off
when all
values are stored.
[2]
Store all
setups
Stores all parameter values for all set-ups in the
non-volatile memory. The selection returns to
[0]
Off
when all parameter values are stored.
9-72 ProfibusDriveReset
Option:
Function:
NOTICE
Resets the VLT
®
PROFIBUS DP MCA
101 option only.
[0]
*
No action
[1]
Power-on reset
Resets frequency converter after power-
up, as for power cycle.
[2]
Power-on reset
prep
[3]
Comm option
reset
When reset, the frequency converter
disappears from the fieldbus, which may
cause a communication error from the
master.
9-75 DO Identification
Range:
Function:
0
*
[0 - 65535 ] Provides information about the DO (drive
object).
9-80 Defined Parameters (1)
Range:
Function:
0
*
[0 - 9999 ] This parameter shows a list of all the defined
frequency converter parameters available for
PROFIBUS.
9-81 Defined Parameters (2)
Range:
Function:
0
*
[0 - 9999 ] This parameter shows a list of all the defined
frequency converter parameters available for
PROFIBUS.
Parameter Descriptions
Programming Guide
MG07C102
Danfoss A/S © 12/2015 All rights reserved.
79