Vertical installation with shaft facing downward
130BC477.10
Fa = 380 N
Fa = 360N
Illustration 12.22 Permitted Forces (ISD/IEC Servomotor with
Brake) for Vertical Installation with Shaft Facing Downward
Radial Force in N
Axial Force in N
Max. Speed in RPM
1200
200
1500
800
300
1500
400
300
1500
200
360
1500
Table 12.9 Combinations of Permitted Forces (ISD/IEC Servomotor
with Brake for Vertical Installation with Shaft Facing Downward
Specifications
VLT
®
ISD 410 Servomotor Operating Instructions
MG75D102 - VLT
®
is a registered Danfoss trademark