![Danfoss VLT Integrated Servo Drive ISD 510 System Operating Instructions Manual Download Page 91](http://html1.mh-extra.com/html/danfoss/vlt-integrated-servo-drive-isd-510-system/vlt-integrated-servo-drive-isd-510-system_operating-instructions-manual_3555656091.webp)
11.2 Servo Access Box
11.2.1 Nameplate
The following data is shown on the SAB nameplate:
130BE612.10
VLT Servo Access Box
P : 8.47KW(400V) / 10.18KW(480V)
Input: 3x400-480V 50/60Hz 12.5A
Output: 565VDC - 679VDC / 15A
Ambient: 50˚C/122˚F Enclosure: IP20
PART NO: 000X0000
SERIAL NO: 000000M000
000X00000000000M000
Made in Germany
UL xxxxx
CAUTION:
WARNING:
See manual for special condition/mains fuse
Voir manuel de conditions spéciales/fusibles
Stored charge, wait 10 min.
Charge residuélle, attendez 10 min.
N
1
2
3
4
5
1
Rated power
4
Ambient temperature
2
Supply voltage
5
Protection rating
3
Output voltage
–
–
Illustration 11.8 SAB Nameplate
Ensure that the nameplate is clearly legible.
11.2.2 Characteristic Data
Definition
Value and unit
Input
Input voltage
400–480 V
±
10%
Efficiency
98.5% at 400 V
Input current
12.5 A continuous
20 A intermittent
Output
Output voltage
ISD Line 1: UDC 1 & ISD Line 2: UDC 2
565–679 V
±
10%
2)
Output voltage
ISD Line 1: STO 1 & ISD Line 2: STO 2
24 V
±
10%
Output voltage
ISD Line 1: AUX 1 & ISD Line 2: AUX 2
24–48 V
±
10%
Output current
ISD Line 1: AUX 1 & ISD Line 2: AUX 2
15 A
Output current UDC
15 A
Output current
ISD Line 1: STO 1 & ISD Line 2: STO 2
1 A
1)
Output power
8.47–10.18 kW
2)
Housing
Dimensions (W x H x D)
130 x 268 x 80 mm
Weight
8.3 kg
Table 11.7 Servo Access Box Characteristic Data
1) Depends on the number of servo drives connected in the
application. The current per drive is 6.7 mA
2) Depends on the input voltage.
Specifications
Operating Instructions
MG75K102
Danfoss A/S © 12/2015 All rights reserved.
89
11
11