Illustration 6.22 Local Area Connection 2 Properties
Disable the
IPv4 Checksum offload
on the network
interfaces as described in
chapter 6.5.4.1 Network Settings
How to set the correct Ethernet POWERLINK
®
master IP
address:
1.
Open the
Network and Sharing Center
.
2.
On the left, click on
Change adapter settings
.
3.
Right-click on the network interface used for
fieldbus communication and select
Properties
.
4.
Click on
Internet Protocol Version 4 (TCP/IPv4)
(the
checkbox must be checked) and then click on
Properties
.
5.
Select
Use the following IP address
and use
192.168.100.240 as the IP address and
255.255.255.0 as the subnet mask. Leave all other
fields empty.
Illustration 6.23 Internet Protocol Version 4 (TCP/IPv4)
Properties
6.5.4.3 Network Settings for Direct
Communication with EtherCAT
®
No EtherCAT
®
-specific network interface configuration
needs to be performed on the ISD Toolbox host PC.
Commissioning
Operating Instructions
MG75K102
Danfoss A/S © 12/2015 All rights reserved.
59
6