![Danfoss VLT Integrated Servo Drive ISD 510 System Design Manual Download Page 62](http://html1.mh-extra.com/html/danfoss/vlt-integrated-servo-drive-isd-510-system/vlt-integrated-servo-drive-isd-510-system_design-manual_3558880062.webp)
6.1.5.5 Speed-Torque Characteristics: Size 2,
2.9 Nm at 25
°
C Ambient
Temperature
2
3
4
1
0.00
2.00
4.00
6.00
8.00
10.00
12.00
M [N
m]
0
500
1000
1500
2000
2500
3000
3500
4000
n [rpm]
130BF920.10
1
SOA 680 V
2
S3
3
SOA 560 V
4
S1
Illustration 6.15 Performance at 25
°
C Ambient Temperature:
Size 2, 2.9 Nm
6.1.5.6 Speed-Torque Characteristics: Size 2,
2.9 Nm at 40
°
C Ambient
Temperature
0.00
2.00
4.00
6.00
8.00
10.00
12.00
M [N
m]
0
500
1000
1500
2000
2500
3000
3500
4000
n [rpm]
2
3
4
1
130BF921.10
1
SOA 680 V
2
S3
3
SOA 560 V
4
S1
Illustration 6.16 Performance at 40
°
C Ambient Temperature:
Size 2, 2.9 Nm
6.1.5.7 Speed-Torque Characteristics: Size 2,
3.8 Nm at 25
°
C Ambient
Temperature
0.00
2.00
4.00
6.00
8.00
10.00
12.00
14.00
M [N
m]
0
500
1000
1500
2000
2500
3000
3500
n [rpm]
2
3
4
1
130BF922.10
1
SOA 680 V
2
S3
3
SOA 560 V
4
S1
Illustration 6.17 Performance at 25
°
C Ambient Temperature:
Size 2, 3.8 Nm
6.1.5.8 Speed-Torque Characteristics: Size 2,
3.8 Nm at 40
°
C Ambient
Temperature
0.00
2.00
4.00
6.00
8.00
10.00
12.00
14.00
M [N
m]
0
500
1000
1500
2000
2500
3000
3500
n [rpm]
2
3
4
1
130BF923.10
1
SOA 680 V
2
S3
3
SOA 560 V
4
S1
Illustration 6.18 Performance at 40
°
C Ambient Temperature:
Size 2, 3.8 Nm
Specifications
VLT
®
Integrated Servo Drive ISD
®
510 System
60
Danfoss A/S © 08/2017 All rights reserved.
MG36C102
6
6