VLT
®
FCM Series
Installation
■
Quick menu mode versus Menu mode
The FC motor series can be used for practically
all assignments, which is why the number of
parameters is quite large. Also, this series offers
a choice between two programming modes - a
Menu mode and a Quick menu mode.
•
The Quick menu takes the user through a number
of parameters that may be enough to get the
motor to run nearly optimally, if the factory setting
for the other parameters takes the desired control
functions into account, as well as the configuration
of signal inputs/outputs (control terminals).
•
The Menu mode makes it possible to select
and change all parameters at the user
’
s option.
However, some parameters will be "missing",
depending on the choice of configuration (parameter
100), e.g. open loop hides all the PID parameters.
In addition to having a name, each parameter is linked
up with a number which is the same regardless of
the programming mode. In the Menu mode, the
parameters are divided into groups, with the first digit
of the parameter number (from the left) indicating the
group number of the parameter in question.
Regardless of the mode of programming, a change
of a parameter will take effect and be visible both in
the Menu mode and in the Quick menumode.
■
Quick Setup via Quick menu
The Quick Setup starts with pressing the [QUICK
MENU] key, which brings out the following
read-out on the display:
50.0 Hz
SETUP
1
QUICK MENU X OF Y
001 LANGUAGE
ENGLISH
At the bottom of the display, the parameter number
and name are given together with the status/value
of the first parameter under Quick Setup. The first
time the [Quick Menu] key is pressed after the unit
has been switched on, the read-outs will always
start at pos. 1 - see table below.
■
Parameter selection
The selection of parameter is effected by means of the
[+/-] keys. The following parameters are accessible:
Pos.:
No.:
Parameter:
Unit:
1
001
Language
2
200
Direction of rotation
3
101
Torque characteristic
4
204
Min. reference
[Hz]
5
205
Max. reference
[Hz]
6
207
Ramp up time
[sec.]
7
208
Ramp down time
[sec.]
8
002
Local/remote control
9
003
Local reference
10
500
Bus address
■
Menu mode
The Menu mode is started by pressing the [MENU] key,
which produces the following read-out on the display:
50.0 Hz
FREQUENCY
0 KEYB.&DISPLAY
Line 3 on the display shows the parameter
group number and name.
■
Parameter groups
In the Menu mode the parameters are divided
into groups. Selection of parameter group is
effected by means of the [<>] keys.
The following parameter groups are accessible:
Group no.
Parameter group:
0
Operation & Display
1
Load & Motor
2
References & Limits
3
Inputs & Outputs
4
Special functions
5
Serial communication
6
Technical functions
*For information on parameter group 800 and 900
for PROFIBUS, please see the FCM Profibus manual
MG.03.EX.YY.
When the desired parameter group has been
selected, each parameter can be chosen by
means of the [+/-] keys:
MG.03.H3.02 - VLT is a registered Danfoss trademark