11.9.3.2 Ethernet Connectors on DAM 510
Table 137: Ethernet Connectors on DAM 510
Connector name
Description
Pins
Ratings
X1 IN
Ethernet IN
1: TX+
2: TX–
3: RX+
4: –
5: –
6: RX–
7: –
8: –
According to standard 100BASE-T.
X2 OUT
Ethernet OUT1 (connection to hybrid cable)
X3 OUT
Ethernet OUT2
11.9.4 I/O Connectors
11.9.4.1 I/O Connector on PSM 510/ACM 510
1
2
3
4
e3
0b
g4
58
.1
1
Illustration 144: I/O Connector on PSM 510 (I/O PSM) and ACM 510 (I/O ACM)
Table 138: Pin Assignment of I/O Connector on PSM 510/ACM 510
Pins
Description
Notes
Rating/parameter
1
DIN1–
Digital input
Input voltage: 0–30 V DC
High (logic "1") voltage: 15–30 V DC
Low (logic "0") voltage: <5 V DC
Maximum input signal frequency: 50 Hz
Maximum input current at 48 V: 11 mA
Maximum input resistance: 4.5 KΩ
2
DIN1+
3
DIG_OUT–
Digital output
Maximum voltage between terminals: 24 V DC or AC
Maximum current: 1 A
Maximum output switching frequency: 50 Hz
4
The conductor cross-section range is 0.2–1.5 mm
2
(AWG 24–AWG 16).
N O T I C E
Only PELV potential can be connected to the digital inputs and outputs.
11.9.5 UAUX Connector
The U
AUX
connector is located on the Power Supply Module (PSM 510).
AQ262449648484en-000101 / 175R1135 | 205
Danfoss A/S © 2020.08
Specifications
VLT® Servo Drive System ISD 510/DSD 510