3.1.20 Parameter Group 0-** Operation/
Display
001
Language
Value:
English (ENGLISH)
[0]
German (DEUTSCH)
[1]
French (FRANCAIS)
[2]
Danish (DANSK)
[3]
Spanish (ESPAÑOL)
[4]
Italian (ITALIANO)
[5]
State when delivered may vary from factory setting.
Function:
The choice in this parameter defines the language to be
used on the display.
Description of choice:
There is a choice of
[0] English
,
[1] German
,
[2] French
,
[3]
Danish
,
[4] Spanish
and
[5] Italian
.
002
Local/remote control
Value:
Remote control (REMOTE)
[0]
Local control (LOCAL)
[1]
Function:
There is a choice of two methods of controlling the FC
motor:
[0] Remote control
and
[1] Local control
.
Description of choice:
If
[0] Remote control
is selected, the FC motor can be
controlled via:
1.
The control terminals or the serial communication
port .
2.
The [Start] key. However, this cannot overrule
Stop commands (also start-disable) entered via
the digital inputs or the serial communication
port.
3.
The [Stop], [Jog] and [Reset] keys, provided that
these are active (see parameters 014, 015 and
017).
If
[1] Local control
is selected, the FC motor can be
controlled via:
1.
The [Start] key. However, this cannot override
Stop commands on the digital terminals (if
[2]
or
[4]
has been selected in parameter 013).
2.
The [Stop], [Jog] and [Reset] keys, provided that
these are active (see parameters 014, 015 and
017).
3.
The [FWD/REV] key, provided that this has been
activated in parameter 016 and that in parameter
013 a choice of
[1]
or
[3]
has been made.
4.
Via parameter 003 the local reference can be
controlled by means of the "Arrow up" and
"Arrow down" keys.
003
Local reference
Value:
Par 013 set for [1] or [2]:
0 - f
MAX
000.000
Par 013 set for [3] or [4] and par. 203 = [0]
set for:
Ref
MIN
- Ref
MAX
000.000
Par 013 set for [3] or [4] and par. 203 = [1]
set for:
-Ref
MAX
- + Ref
MAX
000.000
Function:
This parameter allows manual setting of the desired
reference value (speed or reference for the selected config-
uration, depending on the choice made in parameter 013).
The unit follows the configuration selected in parameter
100, provided that
[3] Process regulation, closed loop
has
been selected.
Description of choice:
[1] Local
must be selected in parameter 002 for this
parameter to be used.
The set value is saved in the case of a voltage dropout, see
parameter 019.
In this parameter Data Change Mode is not exited
automatically (after time out).
Local reference cannot be set via the serial communication
port.
004
Active Setup
Value:
Factory Setup (FACTORY SETUP)
[0]
Setup 1 (SETUP 1)
[1]
Setup 2 (SETUP 2)
[2]
Multi Setup (MULTI SETUP)
[5]
Function:
The choice in this parameter defines the Setup number
you want to control the functions of the FC motor.
All parameters can be programmed in two individual
parameter Setups, Setup 1 and Setup 2. In addition, there
is a pre-programmed Setup, called Factory Setup, that
cannot be modified.
Description of choice:
[0] Factory Setup
contains the factory data. Can be used as
a data source if the other Setups are to be returned to a
known state.
Parameters 005 and 006 allow copying from one Setup to
the other.
[1] Setups 1
and
[2] 2
are two individual Setups that can be
selected as required.
[5] Multi-Setup
is used if remote-mounting switching
between Set-ups is desired. Terminals 2, 3, 4, and 5 as well
Programming
VLT
®
DriveMotor FCM Series
36
MG03BA02 - VLT
®
is a registered Danfoss trademark
3
3
Summary of Contents for VLT Brook Crompton Motor FCM 300
Page 2: ......
Page 37: ...Programming VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 35 3 3...
Page 101: ...Index VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 99...
Page 102: ...www danfoss com drives MG03BA02 175R0087 MG03BA02 Rev 2011 12 22...