3 Programming
3.1 Parameters
3.1.1 Control Panel (175NO131)
The FC motor optionally features a Local Control Panel-
LCP 2 which makes up a complete interface for operation
and monitoring of the FC motor.
IP 65 on front.
3.1.2 LCP Installation
The LCP 2 is connected to the terminal X100, 1-4 (see
separate instruction MI03AXYY).
1.
Service Plug Kit (175N2546) (see
) and cable 175N0162
2.
Plug kit (175N2545) (see
) and cable 175N0162
3.
Remote mounting kit (175N0160) (see
3.1.3 LCP Functions
The functions of the control panel can be divided into
three groups:
•
Display
•
Keys for changing program parameters
•
Keys for local operation
All data are indicated by means of a 4-line alphanumeric
display, which in normal operation is able show 4
measurements and 3 operating conditions continuously.
During programming, all the information required for
quick, effective parameter Set-up of the FC motor will be
displayed. As a supplement to the display, there are three
LEDs for voltage, warning and alarm. All program
parameters of the FC motor can be changed immediately
from the control panel, unless this function has been
blocked via parameter 018.
Illustration 3.1
3.1.4 Display
The LCD display is back lit and has a total of 4 alpha-
numeric lines together with a box that shows the direction
of rotation (arrow) and the chosen Set-up as well as the
Set-up in which programming is taking place if that is the
case.
Illustration 3.2
Programming
VLT
®
DriveMotor FCM Series
28
MG03BA02 - VLT
®
is a registered Danfoss trademark
3
3
Summary of Contents for VLT Brook Crompton Motor FCM 300
Page 2: ......
Page 37: ...Programming VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 35 3 3...
Page 101: ...Index VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 99...
Page 102: ...www danfoss com drives MG03BA02 175R0087 MG03BA02 Rev 2011 12 22...