5.3.27 42-** Safety Functions
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
42-1* Speed Monitoring
42-10 Measured Speed Source
ExpressionLimit
1 set-up
FALSE
-
Uint8
42-11 Encoder Resolution
1024 N/A
1 set-up
FALSE
0
Uint16
42-12 Encoder Direction
[0] Clockwise
1 set-up
FALSE
-
Uint8
42-13 Gear Ratio
1 N/A
1 set-up
FALSE
-4
Uint32
42-14 Feedback Type
[0] With direction info
1 set-up
FALSE
-
Uint8
42-15 Feedback Filter
200 Hz
1 set-up
FALSE
-2
Uint16
42-17 Tolerance Error
120 RPM
1 set-up
FALSE
67
Uint16
42-18 Zero Speed Timer
8760 h
1 set-up
FALSE
74
Uint16
42-19 Zero Speed Limit
120 RPM
1 set-up
FALSE
67
Uint16
42-2* Safe Input
42-20 Safe Function
ExpressionLimit
1 set-up
FALSE
-
Uint8
42-21 Type
[0] NCNC
1 set-up
FALSE
-
Uint8
42-22 Discrepancy Time
10 ms
1 set-up
FALSE
-3
Uint16
42-23 Stable Signal Time
10 ms
1 set-up
FALSE
-3
Uint16
42-24 Restart Behaviour
[0] Manual
1 set-up
FALSE
-
Uint8
42-3* General
42-30 External Failure Reaction
[0] STO
1 set-up
FALSE
-
Uint8
42-31 Reset Source
[0] Drive Reset
1 set-up
FALSE
-
Uint8
42-33 Parameter Set Name
ExpressionLimit
1 set-up
FALSE
0
VisStr[
8]
42-35 S-CRC Value
ExpressionLimit
1 set-up
FALSE
0
Uint16
42-36 Level 1 Password
ExpressionLimit
1 set-up
FALSE
0
VisStr[
8]
42-37 Level 1 Password Buffer
ExpressionLimit
1 set-up
FALSE
0
VisStr[
8]
42-4* SS1
42-40 Type
[0] Delay
1 set-up
FALSE
-
Uint8
42-41 Ramp Profile
[0] Linear
1 set-up
FALSE
-
Uint8
42-42 Delay Time
1 s
1 set-up
FALSE
-1
Uint16
42-43 Delta T
2 %
1 set-up
FALSE
0
Uint8
42-44 Deceleration Rate
1500 /s
1 set-up
FALSE
0
Uint16
42-45 Delta V
120 RPM
1 set-up
FALSE
67
Uint16
42-46 Zero Speed
10 RPM
1 set-up
FALSE
67
Uint16
42-47 Ramp Time
1 s
1 set-up
FALSE
-1
Uint16
42-48 S-ramp Ratio at Decel. Start
50 %
1 set-up
FALSE
0
Uint8
42-49 S-ramp Ratio at Decel. End
50 %
1 set-up
FALSE
0
Uint8
42-5* SLS
42-50 Cut Off Speed
270 RPM
1 set-up
FALSE
67
Uint16
42-51 Speed Limit
150 RPM
1 set-up
FALSE
67
Uint16
42-52 Fail Safe Reaction
[0] STO
1 set-up
FALSE
-
Uint8
42-53 Start Ramp
[0] No
1 set-up
FALSE
-
Uint8
42-54 Ramp Down Time
1 s
1 set-up
FALSE
-1
Uint16
42-6* Safe Fieldbus
42-60 Telegram Selection
[0] None
1 set-up
FALSE
-
Uint8
42-61 Destination Address
1 N/A
1 set-up
FALSE
0
Uint16
42-8* Status
42-80 Safe Option Status
0 N/A
All set-ups
TRUE
0
Uint32
42-81 Safe Option Status 2
0 N/A
1 set-up
TRUE
0
Uint32
42-82 Safe Control Word
0 N/A
All set-ups
TRUE
0
Uint32
42-83 Safe Status Word
0 N/A
All set-ups
TRUE
0
Uint32
42-85 Active Safe Func.
[10] None
All set-ups
TRUE
-
Uint8
42-86 Safe Option Info
0 N/A
All set-ups
TRUE
0
VisStr[
25]
42-87 Time Until Manual Test
8761 h
All set-ups
TRUE
74
Uint16
42-88 Supported Customization File Version
ExpressionLimit
1 set-up
TRUE
-2
Uint16
42-89 Customization File Version
ExpressionLimit
1 set-up
TRUE
-2
Uint16
42-9* Special
42-90 Restart Safe Option
[0] No
All set-ups
FALSE
-
Uint8
Table 5.14
Parameter Lists
Programming Guide
MG33MP02