5 Parameter Lists
5.1 Introduction
Frequency converter series
All = valid for FC 301 and FC 302 series
01 = valid for FC 301 only
02 = valid for FC 302 only
Changes during operation
True means that the parameter can be changed while the
frequency converter is in operation. False means that the
frequency converter must be stopped before a change can
be made.
4 set-up
All set-ups: the parameter can be set individually in each
of the 4 set-ups, for example 1 single parameter can have
4 different data values.
1 set-up: The data value is the same in all set-ups.
Data
type
Description
Type
2
Integer 8
Int8
3
Integer 16
Int16
4
Integer 32
Int32
5
Unsigned 8
Uint8
6
Unsigned 16
Uint16
7
Unsigned 32
Uint32
9
Visible string
VisStr
33
Normalized value 2 bytes
N2
35
Bit sequence of 16 boolean variables
V2
54
Time difference w/o date
TimD
Table 5.1 Data Type
Parameter Lists
Programming Guide
MG33MP02
Danfoss A/S © 10/2018 All rights reserved.
261
5
5