31-02 Bypass Trip Time Delay
Range:
Function:
0 s
*
[0 - 300 s]
31-03 Test Mode Activation
Option:
Function:
[0]
*
Disabled
[1]
Enabled
31-10 Bypass Status Word
Range:
Function:
0
*
[0 - 65535 ]
31-11 Bypass Running Hours
Range:
Function:
0 h
*
[0 - 2147483647 h]
31-19 Remote Bypass Activation
Option:
Function:
[0]
*
Disabled
[1]
Enabled
3.24 Parameters: 32-** MCO Basic Settings
Parameters in this group are available when VLT
®
Motion
Control Option MCO 305 is installed in the frequency
converter. For information about the option, see the
VLT
®
Motion Control Option MCO 305 Operating Instructions.
32-00 Incremental Signal Type
Option:
Function:
[0]
None
[1]
*
RS422 (5V TTL)
[2]
Sinusoidal 1Vpp
[3]
CAN encoder
32-01 Incremental Resolution
Range:
Function:
1024
*
[1 - 1073741823 ]
32-02 Absolute Protocol
Option:
Function:
[0]
*
None
[1]
HIPERFACE
[2]
EnDat
[4]
SSI
[5]
SSI with filter
[6]
BiSS-C
[7]
BiSS-B
32-03 Absolute Resolution
Range:
Function:
8192
*
[0 - 1073741823 ]
32-04 Absolute Encoder Baudrate X55
Option:
Function:
[0]
600
32-04 Absolute Encoder Baudrate X55
Option:
Function:
[1]
1200
[2]
2400
[3]
4800
[4]
*
9600
[5]
19200
[6]
38400
32-05 Absolute Encoder Data Length
Range:
Function:
25
*
[8 - 37 ]
32-06 Absolute Encoder Clock Frequency
Range:
Function:
262 kHz
*
[78.125 - 2000 kHz]
32-07 Absolute Encoder Clock Generation
Option:
Function:
[0]
Off
[1]
*
On
32-08 Absolute Encoder Cable Length
Range:
Function:
0 m
*
[0 - 300 m]
32-09 Encoder Monitoring
Option:
Function:
[0]
*
Off
[1]
3 Channels
[2]
2 Channels
[3]
Warning
[4]
Alarm
32-10 Rotational Direction
Option:
Function:
[1]
*
No action
[2]
Reference reversed
[3]
User units reversed
[4]
Uu and Ref reversed
32-11 User Unit Denominator
Range:
Function:
1
*
[1 - 1073741823 ]
32-12 User Unit Numerator
Range:
Function:
1
*
[1 - 1073741823 ]
32-13 Enc.2 Control
Option:
Function:
[0]
*
No soft changing
[1]
Encoder soft changing enable
[2]
Soft zero setting enable
[3]
Encoder soft changing and soft zero enable
Parameter Descriptions
VLT
®
AutomationDrive FC 301/302
236
Danfoss A/S © 10/2018 All rights reserved.
MG33MP02
3
3