16-82 Fieldbus REF 1
Range:
Function:
0
*
[-200 - 200 ] View the two-byte word sent with the control
word form the Bus-Master to set the reference
value.
For more information, refer to the relevant
fieldbus manual.
16-83 Fieldbus Pos. REF
Range:
Function:
0 CustomRea-
doutUnit2
*
[-2147483648 -
2147483647
CustomRea-
doutUnit2]
NOTICE
This parameter is only
valid with software
version 48.XX.
Shows the 32-bit position
reference sent in PCD 2 and
PCD 3. In parameters related
to PCD 2 and PCD 3, select
[1683] Fieldbus Pos REF
for the
fieldbus which is used by the
frequency converter. The value
is in position units defined in
parameter group 17-7* Position
Scaling
.
16-84 Comm. Option STW
Range:
Function:
0
*
[0 - 65535 ] Show the status word of the extended fieldbus
communication option.
For more information, refer to the relevant
fieldbus manual.
16-85 FC Port CTW 1
Range:
Function:
0
*
[0 -
65535 ]
View the 2-byte control word (CTW) received
from the fieldbus master. Interpretation of the
control word depends on the fieldbus option
installed and the control word profile selected
in
parameter 8-10 Control Word Profile
.
16-86 FC Port REF 1
Range:
Function:
0
*
[-200 -
200 ]
View the 2-byte status word (STW) sent to the
fieldbus master. Interpretation of the status word
depends on the fieldbus option installed and the
control word profile selected in
parameter 8-10 Control Word Profile
16-87 Bus Readout Alarm/Warning
Range:
Function:
0
*
[0 - 65535 ] Alarm and warning numbers in hex as shown
in the alarm log. The high byte contains the
alarm, the low byte contains the warning. The
16-87 Bus Readout Alarm/Warning
Range:
Function:
alarm number is the 1st one that occurred
after the last reset.
16-89 Configurable Alarm/Warning Word
Range:
Function:
0
*
[0 - 65535 ] This alarm/warning word is configured in
parameter 8-17 Configurable Alarm and
Warningword
to match the actual requirements.
3.16.7 16-9* Diagnosis Readouts
NOTICE
When using MCT 10 Set-up Software, the readout
parameters can only be read online, that is as the actual
status. This means that the status is not stored in the
MCT 10 Set-up Software file.
16-90 Alarm Word
Range:
Function:
0
*
[0 - 4294967295 ] Show the alarm word sent via the serial
communication port in hex code.
16-91 Alarm Word 2
Range:
Function:
0
*
[0 - 4294967295 ] View the alarm word sent via the serial
communication port in hex code.
16-92 Warning Word
Range:
Function:
0
*
[0 - 4294967295 ] Show the warning word sent via the
serial communication port in hex code.
16-93 Warning Word 2
Range:
Function:
0
*
[0 - 4294967295 ] View the warning word sent via the serial
communication port in hex code.
16-94 Ext. Status Word
Range:
Function:
0
*
[0 - 4294967295 ] Returns the extended warning word sent
via the serial communication port in hex
code.
16-95 Ext. Status Word 2
Range:
Function:
0
*
[0 - 4294967295 ]
Parameter Descriptions
Programming Guide
MG33MP02
Danfoss A/S © 10/2018 All rights reserved.
215
3
3