8.5 Wiring Configuration for an External
Alarm Reset
Parameters
FC
+24 V
+24 V
D IN
D IN
D IN
COM
D IN
D IN
D IN
D IN
+10 V
A IN
A IN
COM
A OUT
COM
12
13
18
19
20
27
29
32
33
37
50
53
54
55
42
39
130BB928.11
Function
Setting
Parameter E-02 T
erminal 19
Digital Input
[1] Reset
*=Default value
Notes/comments:
Table 8.8 Wiring Configuration for an External Alarm Reset
8.6 Wiring Configuration for Speed
Reference Using a Manual
Potentiometer
Parameters
+10 V
A IN
A IN
COM
A OUT
COM
50
53
54
55
42
39
A53
U - I
≈ 5kΩ
e30bb683.11
FC
Function
Setting
Parameter 6-10
Terminal 53
Low Voltage
0.07 V*
Parameter 6-11
Terminal 53
High Voltage
10 V*
Parameter 6-14
Terminal 53
Low Ref./Feedb.
Value
0 RPM
Parameter 6-15
Terminal 53
High Ref./Feedb.
Value
1500 RPM
*=Default value
Notes/comments:
Table 8.9 Wiring Configuration for Speed Reference
(Using a Manual Potentiometer)
8.7 Wiring Configuration for Speed Up/
Speed Down
Parameters
FC
+24 V
+24 V
D IN
D IN
D IN
COM
D IN
D IN
D IN
D IN
12
13
18
19
20
27
29
32
33
37
e30bb804.12
Function
Setting
Parameter 5-10
Terminal 18
Digital Input
[8] Start*
Parameter 5-12
Terminal 27
Digital Input
[19] Freeze
Reference
Parameter 5-13
Terminal 29
Digital Input
[21] Speed Up
Parameter 5-14
Terminal 32
Digital Input
[22] Speed
Down
*=Default value
Notes/comments:
Table 8.10 Wiring Configuration for Speed Up/Speed Down
130BB840.12
Speed
Reference
Start (18)
Freeze ref (27)
Speed up (29)
Speed down (32)
Illustration 8.4 Speed Up/Speed Down