Parameter 18-39 Temp. Input X48/10
Table 993: Parameter 18-39 Temp. Input X48/10
18-39 Temp. Input X48/10
Default value: 0
Parameter type: Range, -500 - 500
Setup: All setups
Conversion index: 0
Data type: Int16
Change during operation: True
View the actual temperature measured at input X48/10. The temperature unit is based on the selection in
parameter 35-04 Term.
X48/10 Temperature Unit
.
5.18.6 18-4* PGIO Data Readouts
N O T I C E
The following parameters are only available in FC 302
Parameter 18-40 Analog Input X49/1
Parameter 18-41 Analog Input X49/3
Parameter 18-42 Analog Input X49/5
Parameter 18-46 X49 Digital Output [bin]
Parameters for configuring the readout of VLT® Programmable I/O MCB 115.
Parameter 18-40 Analog Input X49/1
Table 994: Parameter 18-40 Analog Input X49/1
18-40 Analog Input X49/1
Default value: 0
Parameter type: Range, -20 - 20
Setup: All setups
Conversion index: -3
Data type: Int32
Change during operation: False
View the actual value at input X49/1 either as a voltage, current or a temperature value.
Parameter 18-41 Analog Input X49/3
Table 995: Parameter 18-41 Analog Input X49/3
18-41 Analog Input X49/3
Default value: 0
Parameter type: Range, -20 - 20
Setup: All setups
Conversion index: -3
Data type: Int32
Change during operation: False
View the actual value at input X49/3 either as a voltage, current, or a temperature value.
Parameter 18-43 Analog Input X49/7
Table 996: Parameter 18-43 Analog Input X49/7
18-43 Analog Input X49/7
Default value: 0
Parameter type: Range, 0 - 30
Setup: All setups
Conversion index: -3
Data type: Int16
Change during operation: False
Shows the actual value at output of terminal X49/7 in V or mA. The value reflects the selection in
parameter 36-40 Terminal X49/7
Analog Output
.
AU275636650261en-000101 / 130R0334