Parameter 17-34 HIPERFACE Baudrate
Table 923: Parameter 17-34 HIPERFACE Baudrate
17-34 HIPERFACE Baudrate
Default value: [4] 9600
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: False
N O T I C E
This parameter cannot be adjusted while the motor is running.
Select the baud rate of the attached encoder. The parameter is only accessible when
parameter 17-20 Protocol Selection
is set to
[1]
HIPERFACE
.
Option
Name
Description
[0]
600
[1]
1200
[2]
2400
[3]
4800
[4]*
9600
[5]
19200
[6]
38400
5.17.4 17-4* Fieldbus Reference 2
Parameter 17-40 Fieldbus Sync. Delta
Table 924: Parameter 17-40 Fieldbus Sync. Delta
17-40 Fieldbus Sync. Delta
Default value: 0
Parameter type: Range, -2147483648 - 2147483647
Setup: 1 setup
Conversion index: 0
Data type: Int32
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Shows the fieldbus synchronizing master position change = master speed when transferred by PCD from fieldbus master.
Parameter 17-41 Fieldbus Profile Velocity
Table 925: Parameter 17-41 Fieldbus Profile Velocity
17-41 Fieldbus Profile Velocity
Default value: 0
Parameter type: Range, 0 - 2147483647 pu/s
Setup: 1 setup
Conversion index: 0
Data type: Int32
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Velocity reference for the profile generator in positioning mode or when using Mode of operation and Profile ositioning mode.
AU275636650261en-000101 / 130R0334
520 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide