Position 4
⇒
Valve
Fan bearings
Pump bearings
Motor bearings
Position 3
⇒
Pump seals
Temperature transmitter
Flow transmitter
Pressure transmitter
Position 2
⇒
Drive system health check
Drive cooling fan
Filter
Fan belt
Position 1
⇒
–
–
–
Warranty
8
hex
+
–
–
–
9
hex
+
–
–
+
A
hex
+
–
+
–
B
hex
+
–
+
+
C
hex
+
+
–
–
D
hex
+
+
–
+
E
hex
+
+
+
–
F
hex
+
+
+
+
Example:
The preventive maintenace word shows 040Ahex:
Position
1
2
3
4
Hex value
0
4
0
A
The 1
st
digit 0 indicates that no items from the 4
th
row require maintenance.
The 2
nd
digit 4 refers to the 3
rd
row indicating that the drive cooling fan requires maintenance.
The 3
rd
digit 0 indicates that no items for the 2
nd
row require maintenance.
The 4
th
digit A refers to the top row indicating that the valve and the pump bearings require maintenance.
Parameter 16-97 Alarm Word 3
Table 911: Parameter 16-97 Alarm Word 3
16-97 Alarm Word 3
Default value: 0
Parameter type: Range, 0 - 4294967295
Setup: All setups
Conversion index: 0
Data type: Uint32
Change during operation: False
Shows the alarm word sent via the serial communication port in hex code.
Parameter 16-98 Warning Word 3
Table 912: Parameter 16-98 Warning Word 3
16-98 Warning Word 3
Default value: 0
Parameter type: Range, 0 - 4294967295
Setup: All setups
Conversion index: 0
Data type: Uint32
Change during operation: False
Shows the warning word sent via the serial communication port in hex code.
5.17 Parameter Group 17-** Feedback
Parameters for configuring the feedback from VLT® Encoder Input MCB 102, VLT® Resolver Input MCB 103m or the drive itself.
AU275636650261en-000101 / 130R0334
516 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide
Summary of Contents for VLT AutomationDrive FC 301
Page 2: ......