4.1.1 Conversion
The various attributes of each parameter are displayed in
Factory Setting. Parameter values are transferred as whole
numbers only. Conversion factors are therefore used to
transfer decimals.
4-12 Motor Speed Low Limit [Hz]
has a conversion factor of
0.1. To preset the minimum frequency to 10 Hz, transfer
the value 100. A conversion factor of 0.1 means that the
value transferred is multiplied by 0.1. The value 100 is
therefore read as 10.0.
Examples:
0s
⇒
conversion index 0
0.00s
⇒
conversion index -2
0ms
⇒
conversion index -3
0.00ms
⇒
conversion index -5
Conversion index
Conversion factor
100
75
74
67
6
1000000
5
100000
4
10000
3
1000
2
100
1
10
0
1
-1
0.1
-2
0.01
-3
0.001
-4
0.0001
-5
0.00001
-6
0.000001
-7
0.0000001
Table 4.2 Conversion Table
4.1.2 Active/Inactive Parameters in Different Drive Control Modes
+ = active
- = not active
AC motor
PM Non salient Motor
U/f mode
VVC
plus
Flux sensorless
Flux w/ motor
feedback
U/f mode
Flux
sensorless
Flux w/
motor
feedback
1-00 Configuration Mode
[0] Speed Open Loop
+
+
+
-
[1] Speed Closed Loop
-
+
-
+
[2] Torque
-
-
-
+
[3] Process
+
+
+
-
[4] Torque Open Loop
-
+
-
-
[5] Wobble
+
+
+
+
[6] Surface Winder
+
+
+
-
[7] Ext. PID Open Loop
+
+
+
-
[8] Ext. PID Closed Loop
-
+
-
+
1-02 Flux Motor Feedback Source
-
-
-
+
-
+
see 1, 2, 3)
+
see 1, 3, 4)
+
see 1, 3, 4)
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
1-20 Motor Power [kW]
(Par. 023 = International)
+
+
+
+
1-21 Motor Power [HP]
(Par. 023 = US)
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Parameter Lists
VLT
®
AutomationDrive Programmming Guide
160
MG33ME02 - VLT
®
is a registered Danfoss trademark
4