4.20 Parameters: 30-** Special Features
4.20.1 30-2* Adv. Start Adjust
30-20 High Starting Torque Time [s]
Range:
Function:
Size related
*
[0 - 60 s] High starting torque time for PM
motors in VVC
+
mode without
feedback.
30-21 High Starting Torque Current [%]
Range:
Function:
Size related
*
[ 0 - 200.0 %] High starting torque time for PM
motors in VVC
+
mode without
feedback.
30-22 Locked Rotor Protection
Option:
Function:
[0]
*
Off
[1]
On
The locked rotor protection for PM motors.
30-23 Locked Rotor Detection Time [s]
Range:
Function:
0.10 s
*
[0.05 - 1 s] The locked rotor detection time for PM
motors.
4.21 Parameters: 32-** Motion Control Basic
Settings
32-11 User Unit Denominator
Range:
Function:
1
*
[1 -
65535 ]
All path information is made in user units and
converted to quad-counts internally. By
selecting scaling units, it is possible to work
with any measurement unit (for example, mm).
This factor consists of a numerator and a
denominator.
32-12 User Unit Numerator
Range:
Function:
1
*
[1 -
65535 ]
All path information is made in user units and
converted to quad-counts internally. By
selecting scaling units, it is possible to work
with any measurement unit (for example, mm).
This factor consists of a numerator and a
denominator.
32-67 Max. Tolerated Position Error
Range:
Function:
2000000
*
[1 -
2147483648 ]
This parameter defines the
maximum error allowed between
the actual position and the
calculated command position. If
the actual error exceeds the value
set in this parameter, the position-
control-fault alarm is triggered.
32-80 Maximum Allowed Velocity
Range:
Function:
1500 RPM
*
[1 - 30000 RPM] This parameter defines the
maximum velocity in RPM during
motion control.
32-81 Motion Ctrl Quick Stop Ramp
Range:
Function:
1000 ms
*
[50 - 3600000
ms]
This parameter defines the quick-
stop ramp time from the
maximum allowed velocity to 0
for motion control.
Parameter Descriptions
VLT
®
AutomationDrive FC 360
112