The IP54 is with 1000 mm (39.4 in) fixed, unshielded cable. Can be used for vertical and horizontal mounting. For horizontal mount-
ing, derating is required.
IP21 and IP65 are with screw terminal for cable termination and can be used for horizontal and vertical mounting. For horizontal
mounting, derating is required.
IP20 is with bolt connection for cable termination. Used for floor mounting.
IP65 is a flat-pack type brake resistor with fixed cable.
150/160%
e7
5u
a0
67
.1
0
Illustration 97: Horizontal Loads
100%
150/160%
e7
5u
a0
68
.1
0
Illustration 98: Vertical Loads
13.2.9.1 Order Numbers for Brake Resistors, T2, Horizontal Braking 10% Duty Cycle
Table 133: Ordering Numbers for Brake Resistors, T2, Horizontal Braking 10% Duty Cycle
FC 202
Horizontal braking 10% duty cycle
Drive data
Brake resistor data
Installation
Danfoss part numbers
Mains
type
P
m
[kW]
R
min
[Ω]
R
br.nom
[Ω]
R
rec
[Ω]
P
br.cont
[kW]
Wire IP54
Screw ter-
minal IP65
Screw ter-
minal IP20
Bolt
con-
nec-
tion
IP20
Cable
cross-
section
[mm
2
(AWG)]
Ther-
mo re-
lay [A]
T2
0.25
(0.34)
380
691.3
630
0.100
175U3002 –
–
–
1.5 (16)
0.4
T2
0.37
(0.50)
380
466.7
410
0.100
175U3004 –
–
–
1.5 (16)
0.5
T2
0.55
(0.75)
275
313.7
300
0.100
175U3006 –
–
–
1.5 (16)
0.6
T2
0.75
(1.0)
188
230
200
0.100
175U3011 –
–
–
1.5 (16)
0.7
T2
1.1
(1.5)
130
152.9
145
0.100
175U3016 –
–
–
1.5 (16)
0.8
T2
1.5
(2.0)
81
110.5
100
0.100
175U3021 –
–
–
1.5 (16)
0.9
T2
2.2
(3.0)
58.5
74.1
70
0.200
175U3026 –
–
–
1.5 (16)
1.6
AJ300847815559en-000101 / 130R0337 | 185
Danfoss A/S © 2020.09
How to Order a Drive
VLT® AQUA Drive FC 202