VLT® 5000 Crane
LCP - Local Control
Panel
■
Display
The LCD-display has back lighting and a total of
4 alpha-numeric lines including a box showing the
direction of rotation (arrow) and the chosen set-up as
well as the set-up in which programming is taking place.
12345678
SETUP
1
12345678901234567890
12345678901234567890
12345678901234567890
175ZA443.10
1st line
2nd line
3rd line
4th line
1st line
shows up to 3 measurements continuously in
normal operating status or a text explaining the 2nd line.
2nd line
shows a measurement with related
unit continuously, regardless of status (except
in case of an alarm/warning).
3rd line
is normally blank and is used in the
menu mode to show the selected parameter
group number and name
4th line
is used in operating status for showing a
status text or in data change mode for showing the
mode or value of the selected parameter.
An arrow indicates the direction of the motor rotation.
■
LEDs
At the bottom of the control panel is a red alarm
LED, a yellow LED and a green voltage LED.
red
yellow
green
If certain threshold values are exceeded, the alarm
and/or warning LED lights up concurrently with a
status and alarm text on the control panel.
■
Display Read-Out State
The display read-out state can be varied - see the list
below - depending on whether the frequency converter
is in normal operation or is being programmed.
■
Display Mode
In normal operation, up to 4 different operating
variables can be indicated continuously: 1.1 and 1.2
and 1.3 and 2, and in line 4 the present operating
status or alarms and warnings that have arisen.
195NA113.10
VAR 2
SETUP
1
STATUS
VAR 1.1 VAR 1.2 VAR 1.3
■
Display Mode - Selection of Read-Out State
There are three options in connection with the
choice of read-out state in the Display mode - I, II
and III. The choice of read-out state determines the
number of operating variables read out.
Read-out state:
I:
II:
III:
Line 1
Description
for operating
variable in line 2
Data value for
3 operating
variables in line
1
Description for
3 operating
variables in line
1
The table below gives the units linked to the variables
in the first and second line of the display.
✭
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.50.N4.02 - VLT is a registered Danfoss trademark
37