1
2
e
3
0
b
g
0
7
3
.1
0
1 Standard
2 PROFIBUS
Illustration 29: FR7/FI7
10. Attach the cover of the drive. For the tightening torques of the screws, see
12.5 Tightening Torques for Cover Screws
that the control cables or the cables of the AC drive are not caught between the frame and the cable cover.
6.5.4 Installing the Cables, FR8/FI8
Context:
Follow these instructions to install the cables and cable accessories.
For information on how to comply with the UL regulations in cable installations, see
.
If it is necessary to connect an external brake resistor, see VACON
®
Brake Resistor Manual. See also
8.7.8.2 Setting the Internal Brake
Electrical Installation
Operating Guide | VACON® NXS/NXP Air-cooled
AQ275638903263en-000301 / DPD00910| 75
Danfoss A/S © 2020.02