Procedure
1. In the
Keypad control
menu (
M3
), find the control mode (
Control Place
) with Menu buttons Up and Down.
READY
STOP
I/O term
e
3
0
b
g
0
3
4
.1
0
Control Place
I/O Terminal
2. To go to the edit mode, push the Menu button Right.
The parameter value starts to blink.
3. To scroll through the options, push the Browser buttons Up and Down.
4. To select the control mode, push the [enter] button.
8.4.4 Keypad Reference
The keypad reference submenu (
P3.2
) shows the frequency reference. In this submenu, also the frequency reference can be edited.
8.4.4.1 Editing the Frequency Reference
Context:
Use these instructions to change the frequency reference.
Procedure
1. In the
Keypad control
menu (
M3
), find the Keypad reference with Menu buttons Up and Down.
2. To go to the edit mode, push the Menu button Right. The frequency reference value starts to blink.
3. Set the new value with the Browser buttons.
The value changes only on the control panel.
4. To make the motor speed to agree with the value on the control panel, select the keypad as the control mode, see
8.4.5 Changing the Rotation Direction
Context:
The keypad direction submenu shows the rotation direction of the motor. In this submenu, also the rotation direction can be changed.
For more information on how to control the motor with the control panel, see
9.2 Commissioning the AC Drive
Using the Control Panel