12.10 Fault Codes
Table 55: Fault Codes
Fault
code
Fault
Subcode
in T.14
Possible cause
How to correct the fault
1
Overcurrent
S1 = Hard-
ware trip
There is too high a current (>4*I H) in
the motor cable. Its cause can be 1 of
the following:
•
a sudden heavy load increase
•
a short circuit in the motor cables
•
the motor is not the correct type
Do a check of the loading.
Do a check of the motor.
Do a check of the cables and connections.
Make an identification run.
S2 = Re-
served
S3 = Cur-
rent con-
troller su-
pervision
S4 = User
configured
overcur-
rent limit
exceeded
2
Overvoltage
S1 = Hard-
ware trip
The DC-link voltage is higher than the
limits.
•
too short a deceleration time
•
high overvoltage spikes in the sup-
ply
•
Start/Stop sequence too fast
Set the deceleration time longer.
Use the brake chopper or the brake resistor.
They are available as options.
Activate the overvoltage controller.
Do a check of the input voltage.
S2 = Over-
voltage
control su-
pervision
3
(1)
Earth fault
The measurement of current tells that
the sum of the motor phase current is
not zero.
•
an insulation malfunction in the ca-
bles or the motor
Do a check of the motor cables and the mo-
tor.
5
Charging
switch
The charging switch is open, when the
START command is given.
•
operation malfunction
•
defective component
Reset the fault and start the drive again.
If the fault shows again, ask instructions from
the local distributor.
6
Emergency
stop
Stop signal has been given from the
option board.
Do a check of the emergency stop circuit.
7
Saturation trip
•
defective component
•
brake resistor short circuit or over-
load
This fault cannot be reset from the control
panel.
Switch off the power.
DO NOT RESTART THE DRIVE or CONNECT
THE POWER!
Ask instructions from the factory. If this fault
shows at the same time with Fault 1, do a
check of the motor cable and the motor.
Specifications
Operating guide | VACON® NXS/NXP Air-cooled
DPD00910G
162 | Danfoss A/S ©
2018.06