•
•
•
•
•
•
•
•
10.481 (ID 1290) Generator Power Limit
Location in the menu:
P2.6.15.19
(Multi-purpose Control Application)
Use this parameter to set the maximum power limit of the generating side.
For Closed Loop control mode only.
10.482 (ID 1316) Response to Brake Fault
Location in the menu:
P2.7.28
(Multi-purpose Control Application)
Use this parameter to set the response type to a brake fault.
10.483 (ID 1317) Brake Fault Delays
Location in the menu:
P2.7.29
(Multi-purpose Control Application)
Use this parameter to set the delay after which the brake fault is activated when there is a mechanical delay in the brake.
See parameter
ID 1210
.
10.484 (ID 1324) Master/Follower Selection
Location in the menu:
P2.11.1
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to select the Master/Follower mode.
When the value Follower is selected, the Run Request command is monitored from Master. All other references are selectable by
parameters.
10.485 (ID 1352) SystemBus Fault Delay
Location in the menu:
P2.7.31
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the maximum time for which the heartbeat is missing before a SystemBus fault occurs.
10.486 (ID 1355) Flux 10%
Location in the menu:
P2.6.18.1
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.1
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the level of flux as a percentage of the nominal flux voltage.
Motor voltage corresponding to 10% of flux as a percentage of nominal flux voltage.
10.487 (ID 1356) Flux 20%
Location in the menu:
P2.6.18.2
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.2
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the level of flux as a percentage of the nominal flux voltage.
Motor voltage corresponding to 20% of flux as a percentage of nominal flux voltage.
10.488 (ID 1357) Flux 30%
Location in the menu:
P2.6.18.3
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.3
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the level of flux as a percentage of the nominal flux voltage.
Motor voltage corresponding to 30% of flux as a percentage of nominal flux voltage.
10.489 (ID 1358) Flux 40%
Location in the menu:
P2.6.18.4
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.4
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the level of flux as a percentage of the nominal flux voltage.
AB296635287482en-000301 / DPD00903
286 | Danfoss A/S © 2023.02
Parameter Descriptions
VACON® NX All-in-One
Application Guide
Summary of Contents for VACON NX
Page 1: ...Application Guide VACON NX All in One drives danfoss com...
Page 2: ......