Operating Guide
Termix VVX Compact 28/18 – 7 Series BS-HC
4.0 Mounting
4.1 Mounting
Installation must be in compliance with local standards and
regulations.
District heating (DH) - In the following sections, DH refers to the
heat source which supplies the substations. A variety of energy
sources, such as oil, gas or solar power, could be used as the
primary supply to Danfoss substations. For the sake of simplicity,
DH can be taken to mean the primary supply.
Connections:
1. District heating (DH) supply
2. District heating (DH) return
3. Domestic hot water (DHW)
4. Domestic cold water (DCW)
5. Hot water circulation (HCW)
6. Heating (HE) supply
7. Heating (HE) return
Connection sizes:
DH + HE:
G 1” (int. thread)
DCW + DHW:
G 1” (int. thread)
HCW:
G ¾” (int. thread)
Dimensions (mm):
Without cover:
H 1140 x W 785 x D 440
With cover:
H 1140 x W 800 x D 522
Weight (approx.):
75 kg
Authorized personnel only
Assembly, start-up and maintenance work must be performed by
qualified and authorized personnel only.
The pipe placement can deviate from the shown drawing. Please note
the markings on the station.
4
DEN-GT
LGB42404