When the EH spool position is forced to neutral, the closed loop control will try to correct the position to avoid the
overshoots by changing the gain in the regulation. (For details on the P3588 and P3589, refer Safety Manual).
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
er
s ‘
S
’
Mi
n
.
M
ax.
IMD - EH-Steering
disengage confidence
limit
P3586
U8
x10ms
Timeout value to declare steering movements to be active if EH-Spool
stays within the limit specified by P3090.
OEM
0
255
30
S
IMD- EH-Spool in
neutral confidence limit
P3587
U8
x10ms
If EH-Spool stays within the threshold specified by P3090 for the timeout
value specified by P3590, IMD overrules EH-Steering algorithms and takes
over spool control to evaluate spool position.
OEM
0
255
15
S
IMD - Dynamic SVC
integral limit
P3588
U8
-
Dynamic SVC integral limit to use while EH-Spool is close to neutral
OEM
0
255
25
S
IMD - Integral gain
P3589
U16
0,1
Dynamic SVC integral gain to use while EH-Spool is close to neutral.
OEM
0
65535
225
S
IMD - Threshold
P3591
U16
x10u Meter
Sterring activation spool threshold is close to neutral
OEM
10
25
15
S
Attention
How to verify the correct operation of IMD, follow below steps:
1.
Check the status message 1 sent by CLS Main and Safety controller, for the requested spool position and actual
spool position. As mentioned above, if the requested spool position is <0.4mm, then the actual spool position is
either fixed to +0.4mm or -0.4mm (based on the previous EH-steering direction). When the steering wheel is
manually being turned, the actual spool position is forced to neutral. If the spool fails to arrive at neutral even
after the turning the steering wheel, then hydraulic over ride is failing to perform.
2.
Check the hydraulic connections (for EHi hydraulic schematics refer EHi TI). There must not be any missing
connections in the EHi configuration.
3.
Check the steering unit pressure, P-T bar in neutral to be below 14 bar (refer service manual of EHi). If higher
than 14 bar IMD may disable EH steering operation.
Important
The PVED-CLS is dedicated for IMD: It has built in check valves between pilot ends of the EH spool to the PE pilot
supply. In this way, its ensured there will be no hydraulic pressure on either end of the spool when the cut off spool
is in safe state, because the pilot supply is connected to tank. For IMD operation use only PVED-CLS including check
valves.
7.4
VALVE CAPACITY
The valve capacity parameter (P3088) must be set to the corresponding EH flow size.
P3088 indicates the EH-spool’s (either in the OSPE, EHi-E, EHi-H or EHPS) maximum output flow, given in liters per
minute. The nominal value for the EH-spool’s maximum output flow can be found on the OEM’s customer drawing.
Depending on the standby pressure for the steering system, the actual maximum output flow will deviate. As default, the
nominal value will in most cases give a very acceptable steering performance in fast-steering mode but for fine-tuning of
P3088, please contact your local Danfoss representative.
Summary of Contents for PVED-CLS
Page 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Page 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Page 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Page 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Page 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...