© Danfoss | August 2018
AQ00000211 |
181
ENGINEERING TOMORROW
17.6.5.3
Post conditions
After a successful manual spool calibration, the calibration counter and bit inverted copy for spool calibration should be
updated as described below:
•
Populate a temporary data sector for “Production/Calibration Flag”. Update the Spool dead-band calibration
counters. Increment P3771 from 0 to 1 and increment bit-wise inverted P3772 from 255 to 254 for the displayed
below,
Production/Calibration Flag
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
Calibration counter - Spool calibration
P3771
U8
-
Calibration counter - Spool calibration
OEM
0
255
0
Bit inverted value for "Calibration counter -
Spool calibration"
P3772
U8
-
Bit inverted value for "Calibration counter - Spool calibration"
OEM
0
255
255
Calibration counter - Analogue WAS
calibration
P3773
U8
-
Calibration counter - Analogue WAS
OEM
0
255
0
Bit inverted value for "Calibration counter -
Analogue WAS calibration"
P3774
U8
-
Bit inverted value for "Calibration counter - Analogue WAS"
OEM
0
255
255
Calibration counter - CAN WAS calibration
P3775
U8
-
Calibration counter - CAN WAS
OEM
0
255
0
Bit inverted value for "Calibration counter -
CAN WAS calibration"
P3776
U8
-
Bit inverted value for "Calibration counter - CAN WAS"
OEM
0
255
255
Calibration counter - Analogue joystick
P3777
U8
-
Analogue sensor based Joystick calibration counter
OEM
0
255
0
Bit inverted value for "Calibration counter -
Analogue joystick"
P3778
U8
-
Bit inverted value for Analogue sensor based Joystick
calibration counter
OEM
0
255
255
Table 91
•
Calculate the sector CRC as CRC-16-CCITT (P3771…P3778) and store (word) at the CRC/Checksum address
(P3789). For example of how to calculate sector CRC, please see paragraph 17.5.2
•
Write data sector “Production/Calibration Flag” to the MAIN-controller
Summary of Contents for PVED-CLS
Page 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Page 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Page 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Page 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Page 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...