System Parameters
Index
Name
Description
Data
Type
Range
Default
Locked
Not
Restored
702
Lspl
Index for controlling linearity of left
flow characteristic
S16
[-10 ; 10]
0
703
Lspr
Index for controlling linearity of right
flow characteristic
[-10 ; 10]
0
706
Vcap
Valve capacity [l/min]
U16
[5; 120]
25
707
StrkVol
Stroke Volume [cm3]
[100 ; 8000]
600
725
RiOSP
Backlash of OSP
[0; 160]
50
726
Sts_backup
Steering sensitivity of back up
system
[300; 700]
500
729
Xspl_1000
Max spool position at left side of
neutral
S16
[-1000; -300] EH/
OSPE
[-1000; -400]
EHPS
-1000
✓
✓
737
Xspl_0
Spool position at left spool dead
band
[-250; 0] EH/OSPE
[-350; 0] EHPS
-185
✓
✓
738
Xspr_0
Spool position at right spool dead
band
[-250; 0] EH/OSPE
[-350; 0] EHPS
185
✓
✓
747
Xspr_1000
Max Spool position at right side of
neutral
[300; 1000] EH/
OSPE
[400; 1000] EHPS
25
✓
✓
748
ClosedLoopXspOffset
Auto-calibration set-point offset
[0; 300]
25
✓
✓
750
Ktol
Tolerance parameter for plausibility
check and steering actuator
dynamics
U16
[500; 1000]
800
758
XspCalibrationOffSet
Auto-calibration set-point offset
S16
[0; 300]
25
✓
✓
798
Ve_100_to_0_time
Fastest time in ms to deceleration
from 100 to 0 km/h
U16
[0; 32000]
0
799
Ve_0_to_100_time
Fastest time in ms to acceleration
from 0 to 100 km/h
832
SensorSupplyVoltage
Sensor supply voltage [mV]. Read
only.
[0; 5100]
833
Temperature
Temperature measured on the
PVED-CL printed circuit board in
degrees C. Read only.
S16
[-50; 451]
931
OperationTime
The time PVED has been operating
since the first boot. Unit: 6 min.
Read-only.
U32
[0 ; 4294967295]
✓