PVE-EX Introduction
The Danfoss PVE-EX is a PVE series 7 actuator for PVG32, PVG100 and PVG120.
The PVE-EX is an explosion proved PVE designed to be used in harsh environments like mining and oil
and gas industries.
The PVE-EX has been certified by NEMKO, IECEx and MA.
Literature Reference
Literature reference for PVG and PVE products
Title
Type
Order number
PVG 32 Proportional Valve Groups
Service Manual
11039167
PVG 100 Proportional Valve Groups
Service Manual
11048807
PVG 32 Proportional Valve Groups
Technical Information
520L0344
PVG 100 Proportional Valve Groups
Technical Information
520L0720
PVG 120 Proportional Valve Groups
Technical Information
520L0356
PVG 32 Metric ports
Technical Information
11051935
Product Certification
The PVE-EX db version is developed according to and in compliance:
•
EN ISO 4413:2010 Hydraulic fluid power - General rules and safety requirements for systems and their
components
•
EN 60079-0:2012/A11:2013, IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General
requirements
•
EN/IEC 60079-1:2014 Electrical apparatus for explosive gas atmospheres-part 1: Flameproof
enclosures “d”
Installation and Maintenance standards:
•
EN/IEC 60079-14 Explosive atmospheres - Part 14: Electrical installations design, selection and
erection
•
EN/IEC 60079-17 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
The PVE-EX is in conformity with listed EU Directive(s):
•
EMC Directive 2004/108/EC
•
EN/IEC 61000-6-2:2005 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity
for industrial environments
•
EN 61000-6-4:2007/A1:2011, IEC 61000-6-4:2006 Electromagnetic compatibility (EMC) - Part 6-4:
Generic standards - Emission standard for industrial environments
Protection
All PVE-EX modules comply with protection class IP66 and IP69k according to EN60529. However, in
particularly exposed applications, protection in the form of shielding is recommended.
Warnings
Before implementing actuators in any application, read all warnings.
Warnings are listed next to the most relevant section and repeated in Warnings chapter.
Technical Information
Electrohydraulic Actuators PVE-EX
General information
©
Danfoss | October 2017
BC00000393en-US0102 | 5