Output types
•
Digital (DOUT)
•
Pulse Width Modulated (PWM/DOUT/PVGOUT)
Output pins available on SC Controller Family
SC Controller
DOUT (3 A)
PWMOUT/DOUT/(3 A)
SC024-110/112
4
SC024-120/122
8
SC050-120/122
6
8
SC050-13H
6
8
The power pin of a PVG valve should only be connected to a digital output.
PLUS+1
®
control modules feature user-configurable output pin parameters. Output pin parameters
are configured using PLUS+1
®
GUIDE templates.
Refer to module data sheets for maximum output current ratings of individual modules. The total
output current for any PLUS+1
®
module must not exceed the maximum allowable current specified in
the module data sheet.
W
Warning
Unintended movement of the machine or mechanism may cause injury to the technician or
bystanders. The module will be powered up if battery voltage is applied to the module's output pin.
To protect against unintended movement, secure the machine.
C
Caution
Warranty will be voided if module is damaged by significant current driven back through an output
pin.
Digital (DOUT)
Digital outputs can source up to 3 A.
General
Description
Comment
Configuration
Sourcing only.
Type
Linear switching.
Short circuit to ground protection
Non-damage, current/thermal limit with status indication; automatic latch off /resume.
Open circuit detection
Fault indication provided. The GUIDE Pin Status requires a load of 0.22 A to be
connected or an open fault will be declared.
Parallel operation
Digital outputs from the same module are capable of being connected together such
that the net current rating is the sum of the individual ratings; timing is resolved by the
operating system; diagnostic capability is maintained.
Shut off
Processor control with hardware WatchDog override.
Technical Information
PLUS+1 SC0XX-1XX Controller Family
Outputs
12 |
©
Danfoss | June 2016
L1415500 | BC00000235en-US0201