background image

Technical Information

PLUS+1® Mobile Machine Displays

DP570 Series

powersolutions.danfoss.com

Summary of Contents for PLUS+1 DP570 Series

Page 1: ...Technical Information PLUS 1 Mobile Machine Displays DP570 Series powersolutions danfoss com...

Page 2: ...system text changes 0601 July 2015 Vault memory removed reference to USB port DP570 does not have one FB March 2015 Various FA February 2015 Converted to Danfoss layout Ingress Protection IP rating u...

Page 3: ...n 12 Encoder 14 Video 14 Outputs 14 Video power output 14 Controller Area Network CAN specifications CAN shield analog inputs 15 CAN communication 15 Memory NV memory 16 FRAM Memory 16 Vault Memory 16...

Page 4: ...rmation regarding pin characteristics PLUS 1 GUIDE User Manual This user operation manual OM details information regarding the PLUS 1 GUIDE tool set that is used to build PLUS 1 applications This OM c...

Page 5: ...esponsibility for Danfoss products being incorrectly applied or the system being programmed in a manner that jeopardizes safety All safety critical systems shall include an emergency stop to switch of...

Page 6: ...ghted software licensed under the GPL Version 2 0 or LGPL Version 2 1 Linux operating system software is free software you can redistribute it and or modify it under the terms of the GNU General Publi...

Page 7: ...Machine Displays B Input output options Code Description 01 User configurable 1 CAN 2 DIN AIN 2 DIN AIN 4 20 mA 2 Multi function 1 DOUT or 2 CAN 2 DIN AIN 4 20 mA 2 Multi function 1 DOUT C Real time c...

Page 8: ...it 16 to 22 AWG 10102025 DEUTSCH DTM06 12SA 12 pin connector kit 20 AWG 10100944 Connection kit DP570 with camera cable 11145163 Accessories Description Part numbers Panel mounting kit 11140430 PLUS 1...

Page 9: ...High range multifunction input Description Unit Minimum Maximum Comment Range mV 0 37 296 Resolution mV 14 3 Worst case error V 1 296 Input impedance k 110 2 To 0 V Input impedance with pull down k 13...

Page 10: ...Range mA 0 5 43 Resolution A 21 Worst case error mA 1 7 Over the full temperature range 30 C to 60 C 22 F to 140 F Input impedance 100 76 0 1 Technical Information DP570 Series Displays Inputs output...

Page 11: ...pullup HiV Vin Rxhipulldn HiV Vin Rxhipullboth HiV Vin Vin 9 12 15 18 21 24 27 30 33 36 5000 11500 18000 24500 31000 37500 44000 50500 57000 63500 70000 70000 5000 36 9 Technical Information DP570 Ser...

Page 12: ...on Minimum Typical Maximum Comment Minimum discernible voltage 0 mV 20 mV Maximum discernible voltage 5 62 V 5 75 V 5 88 V Precision 2 14 mV Worst case error 130 mV Over the full temperature range 30...

Page 13: ...7 1 k Pull to 2 5V Resistance input Description Unit Minimum Maximum Comment Range 0 10000 Resolution Source current mA 0 3 6 When configured as a resistance rheostat temp sensor input the device wil...

Page 14: ...crements or decrements the counter according to the phase sequence The counter is incremented decremented on every low to high and high to low edge of the A signal Some encoders with detents give a co...

Page 15: ...6 Measuring range V 0 5 75 Resolution mV 1 4 Worst case error mV 20 U 2 Input impedance k 233 3 CAN communication There are two stand alone CAN busses Both CAN ports are software configurable and can...

Page 16: ...of over 100 trillion cycles which is ideal for datalogging 2kB is available for application Vault Memory DP570 Series Displays have 16 MB of flash vault memory application logging memory Application...

Page 17: ...4 60 140 Storage temperature C F 30 22 80 176 Ingress Protection IP rating IP67 With mating connector installed and sealing plugs in unused connections W Warning Excessive high low operating storage t...

Page 18: ...al continued Condition Rating Bump IEC 60068 2 29 Shock IEC 60068 2 27 Free fall IEC 60068 2 32 Technical Information DP570 Series Displays Product ratings 18 Danfoss January 2017 L1328765 BC00000231e...

Page 19: ...will break if hit with a hard or heavy object If the protective glass is broken remove the display from your machine then return the display to Danfoss to be serviced Clean the display s housing and p...

Page 20: ...ions in millimeters 36 20 173 40 115 20 86 40 7 00 39 70 169 40 144 78 LCD 4 x 8 75 00 49 2 63 7 kwa1422303242511 Technical Information DP570 Series Displays Installation 20 Danfoss January 2017 L1328...

Page 21: ...mm maximum thickness 4 Panel bracket 5 M4X10 screws with lock washers 4X Stand alone on post Post mounting option in millimeters 41 50 6 0 75 00 49 2 63 7 1 2 3 4 kwa1422368364473 1 4X insert for M4...

Page 22: ...ideo Power Ground C1 P2 Power Input C2 P2 Video Power Supply C1 P3 CAN0 High C2 P3 Video Signal Input 1 C1 P4 CAN0 Low C2 P4 Video Signal Ground C1 P5 CAN Shield C2 P5 NC C1 P6 CAN1 High or DIN AIN C1...

Page 23: ...hors that will allow wires to float with respect to the machine rather than rigid anchors C Caution Unused pins on mating connectors may cause intermittent product performance or premature failure Plu...

Page 24: ...6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No...