MP20V receiver installation
The below information describes hazards to be aware of during installation and steps to locate the
receiver.
Risk of shock
Completely shut down the machine when installing the receiver.
Check the power supply and shut off the main switch to disconnect the interface cable between the
receiver and the machine's electrical box.
1. Find an easily accessible and clear location with a direct vision between the receiver's antenna and
the transmitter's working area.
2. Optional: If it is difficult to achieve direct vision between the receiver's antenna and the transmitter's
working area, it is recommended to use an extended antenna in a clear location (only for models that
allow an antenna).
In areas of high vibration, the use of dampers is advised.
3. Proceed to connect the power supply. Use the connection block diagram provided with the system,
where the correspondence between the transmitter maneuvers and the receiver's outputs are
detailed.
1
2
3
4
5
6
7
15
16
17
18
19
20
21
29
30
31
32
33
34
35
43
44
45
46
47
48
49
57
58
59
60
61
62
63
22
23
24
25
26
27
28
36
37
38
39
40
41
42
50
51
52
53
54
55
56
64
65
66
67
68
69
70
8
9
10
11
12
13
14
4. Check if the electrical installation and verify if there's an option to connect the neutral or the ground
cable. In that case, don't forget to connect the ground cable.
The use of fireproof or flame retardant cables are recommended for the connection.
User Manual
MP20V Receiver
Installation
8 |
©
Danfoss | January 2019
BC292570533618en-000101
Summary of Contents for MP20 Series
Page 1: ...User Manual Remote Control MP20V Receiver www danfoss com...
Page 10: ...User Manual MP20V Receiver Installation 10 Danfoss January 2019 BC292570533618en 000101...
Page 14: ...User Manual MP20V Receiver 14 Danfoss January 2019 BC292570533618en 000101...
Page 15: ...User Manual MP20V Receiver Danfoss January 2019 BC292570533618en 000101 15...