4.3 Wiring Diagram
FC300
Reference index Bit 1
Enable (error clear in dig. control mode)
Reference index Bit 4
Reference index Bit 3
Reference index Bit 2
Touchprobe pos. locked
Manual Jog positive
Reset Touchprobe pos.
Go to Home position
Latch new index
2
Homing completed
Reference pos. reached
Reference index Bit 0
Reference index Bit 1
Reference index Bit 2
Reference index Bit 3
Reference index Bit 4
02
03
04
06
+24 V DC out
+8 V DC out
+5 V DC out
COM
+24 V DC out
+8 V DC out
+5 V DC out
COM
A
/A
B
/B
CLK
/CLK
DATA
/DATA
Analog
Output
Analog
Inputs
S201, S202 = Off
MCO 351
Relay
01
Relay
02
Mains
Motor
X56
Encoder 1
X55
Encoder 2
+24 V OUT
+24 V OUT
Reference index Bit 0
COM D in
Safe torque off (STO)
COM A in
+10 V OUT
Quickstop
Manual Jog negative
COM A out
Touchprobe switch
Positive HW limit switch
Negative HW limit switch
Home reference switch
Go to target position
Reset Home flag
+24 V supply
COM
Error occured
12
13
18
19
27
29
32
33
20
37
39
42
50
53
54
55
1
2
3
4
5
6
7
8
9
10
1
1
2
3
4
5
6
7
8
Digital
Inputs
X57
Digital
Inputs
X58
24 V DC
Supply
X59
Digital
Outputs
91
92
93
PE
96
97
98
99
U
V
W
01
Brake Supply
Brake Brake COM
05
L1
L2
L3
PE
PE
TTL
SSI
SINCOS
A
/A
B
/B
Z
/Z
CLK
/CLK
DATA
/DATA
SIN
REFSIN
COS
REFCOS
1
2
3
4
5
6
7
8
9
10
11
12
Z
/Z
1
2
3
4
5
6
7
8
9
10
11
12
130BD658.10
Illustration 4.5 Wiring Diagram
NOTICE
Input 29 is not available in FC 301. Therefore only 16 positions can be selected via digital inputs in FC 301.
Electrical Installation
Operating Instructions
MG33R302
Danfoss A/S © 04/2014 All rights reserved.
13
4
4