General Specifications
Features
Description
Design
U-style HST with variable displacement piston pump and fixed motor
Direction of Rotation
Clockwise / Counterclockwise
Pipe Connections
Main Pressure ports: SAE O-Ring Boss
Recommended Installation Position
Discretionary: The housing must be filled with hydraulic fluid
LDT physical properties
Features
Units
LDT21
LDT24
LDT32
Displacement
Pump side
cm
3
/rev [in
3
/rev]
0-21 [0-1.28]
0-24 [0-1.46]
0-31.5 [0-1.92]
Motor side
21 [1.28]
24 [1.46]
31.5 [1.92]
Mass moment of inertia
of rotating components
Pump side
kg•m
2
[slug•ft
2
]
0.000878 [0.000648]
0.000869 [0.000641]
0.001400 [0.001033]
Motor side
0.000693 [0.000512]
0.000860 [0.000634]
0.001370 [0.001011]
Weight (dry)
kg [lb]
11.2 [24.7]
14.0 [30.9]
21.0 [46.3]
Oil volume
Case only
liter [US gal]
0.9 [0.24]
1.1 [0.29]
1.4 [0.38]
With passage
1.0 [0.26]
1.2 [0.31]
1.5 [0.41]
Installation
See
Rotation
Clockwise
Clockwise
Clockwise
Ports (ISO 11926-1)
See
Input shafts and PTO shafts
Output shaft
Control type
LDT Operating Parameters
Features
Units
LDT21
LDT24
LDT32
Input speed
Minimum
min
-1
(rpm)
500
500
500
Rated
3600
3400
3200
Maximum
3800
3800
3400
Output speed
Minimum
min
-1
(rpm)
500
500
500
Rated
3600
3400
3200
Maximum
3800
3800
3400
System pressure
Maximum working
pressure
bar [psi]
250 [3626]
300 [4350]
300 [4350]
Maximum pressure
280 [4061]
345 [500]
345 [500]
Input power
Maximum
kw [hp]
22 [30]
26 [35]
29.8 [40]
Charge pressure
Minimum
bar [psi]
5 [73]
5 [73]
5 [73]
Case pressure
Rated
bar [psi]
1 [14.5]
1 [14.5]
1 [14.5]
Maximum
3 [43.5]
3 [43.5]
3 [43.5]
Service Manual
LDT 21/24/32 Closed Circuit Axial Piston Transmission
Technical Specifications
14 |
©
Danfoss | June 2022
AX417167456877en-000101