Inputs – Sensor Power
The status of sensor power input on the connector and pin C1p06 is described.
Signal
Type
Direction
Range
Description
C1p06_SnsrPwr
Bus
——
——
AnIn U16
Input
0 – 32767
Analog input AD count.
Due to CAN message optimization, this value is approximated by scaling the Volt
signal.
Volt U16
Input
0 – 10000
Analog input voltage
100 is 100 mV.
Updated BOOL
Input
——
True when the AnIn and Volt signals are refreshed.
Inputs – Multifunction Inputs
The status of multifunction inputs on the connectors and pins C1p08, C1p09, and C1p10 is described.
Signal
Type
Direction
Range
Description
Pin _MFIn
Bus
——
——
Config
Bus
——
——
PinConfig0 U16
Output
0 – 3
Determines how the input pin is internally connected.
0: Activated with 5 V or Supply Voltage. The internal Pull Down and Pull Up
resistors are disabled.
1: Activated with Ground. The internal Pull Up resistor is connected to an internal
5 V. The internal Pull Down resistor is disabled.
2: Activated with 5 V or Supply Voltage. The internal Pull Up resistor is disabled.
The internal Pull Down resistor is connected to Ground.
3: Activated with Supply Voltage. The internal Pull Up resistor is connected to an
internal 5 V. The internal Pull Down resistor is connected to Ground.
PinConfig1 U16
Output
0 – 3
Sets the maximum input voltage to allow maximum possible input resolution.
0: 0 – 5.753 V
1: 0 – 0.448 V
2: 0 – 37.4 V
3: 0 – ~2.918 V (not recommended)
PinConfig1 U16
Output
0 – 3
Sets the maximum input voltage to allow maximum possible input resolution.
0: 0 – 5.26 V
1: 0 – 0.3675 V
2: 0 – 35.3 V
3: 0 – ~2.465 V (not recommended)
DigInConfigHigh
U16
Output
0 – 65535
DigInConfigHigh is the voltage level required for DigIn to transition from false to
true.
100 is 100 mV.
DigInConfigLow U16
Output
0 – 65535
DigInConfigLow is the voltage level required for DigIn to transition from true to
false.
100 is 100 mV.
DigIn
BOOL
Input
——
Digital input state according to PinConfig0, DigInConfigHigh and
DigInConfigLow.
AnIn
U16
Input
0 – 32767
Analog input AD count.
Due to CAN message optimization, this value is approximated by scaling the Volt
signal.
Volt
U16
Input
0 – 37400
Analog input voltage.
The actual maximum value is determined by PinConfig1.
100 is 100 mV.
Freq
U16
Input
0 – 35300
Input Signal Frequency
100 is 100 Hz.
User Manual
PLUS+1® Compliant IX012-010 Function Block
IX012-010 Function Block
6 |
©
Danfoss | July 2018
11063398 | AQ00000107en-US0101