background image

Danfoss does not take responsibility for incorrect installation or
any frequency interference.

Chance of unintended machine movement on start up.
Ensure the machine is stopped for the entire duration of the
assembly process.
Keep the work area free and wear protective clothing.

To maximize product life, it is essential to use Danfoss original
BT11K batteries.

1.

Connect the power supply and the outputs according to
the connection block diagram provided with the system.

The configuration of the radio node can last up to 1 minute.

2.

Insert the EEPROM and the batteries.

3.

Push and pull out the STOP button.

The status LED will pulse blue until the stand by mode is
reach, then it will turn into a continuous blue.

[1]

[2]

[3]

I

II

4.

Press the start button.

The status LED will pulse green until the transmitter is
linked with the receiver. The LED will turn into a continuous
green when the receiver confirms the link.

RX

I

II

 

 

RX

I

II

The system is now fully operational.