background image

2. Place the batteries in the compartments of the battery charger.

3. Optional: If charging multiple batteries, wait at least 5 seconds before placing the second battery in

the other compartment.

Possible damage to battery!

Be sure to charge batteries in environments with temperatures over 0° C.

CB70 status LEDs

Each battery compartment has an LED that indicates the status of the batteries' charge.

Green LED; pulsing

Battery is excessively depleted

Green LED; continuous

Normal charging operation mode

Green LED; off

Battery charging process is complete

The battery charger must be placed and used out of the danger area.

Battery Charging Recommendations

The battery lifespan is estimated to 500 recharging cycles and is largely dependent on the conditions of

use. To maximize the lifespan of the batteries and battery charger, follow these recommendations:

Do not recharge the battery until it is completely flat, as shown with red LED slow pulse on the
transmitter

Always charge the batteries at temperatures between 0° and 45°C (the batteries will not become fully
charged at temperatures exceeding 45°C)

Do not leave the battery charger or batteries in a direct sunlight

Charge batteries at least once every six months

Avoid short circuits between the battery contacts; do not carry charged batteries in toolboxes or next
to other metal objects (keys, coins, etc.)

Always keep contacts clean

Caution! Risk of Explosion if Battery is Replaced by an incorrrect type. Non Danfoss Battery use may
void warranty

User Manual

Remote Control IK4 Transmitters

Charger and battery

 

©

 Danfoss | May 2021

BC290863558440en-000201 | 13

Summary of Contents for IK4

Page 1: ...User Manual Remote Controls IK4 Transmitters www danfoss com...

Page 2: ...s Date Changed Rev May 2021 Added trouble shooting and start up information for TR2400 0201 February 2019 Rebranded to Danfoss Power Solutions 0101 User Manual Remote Control IK4 Transmitters 2 Danfos...

Page 3: ...Maintenance Maintenance tips 10 Troubleshooting 400 900 MHz 10 Troubleshooting 2 4 GHz 10 Charger and battery Charger and battery 12 CB70 and BT27IK specifications 12 Setting up the CB70 battery char...

Page 4: ...llage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement IK4 General Safety The following saf...

Page 5: ...s press STOP before plugging in tether cable if applicable Remove the Tether connection on the transmitter First if applicable Do not operate product when visibility is limited Make sure product is co...

Page 6: ...8 185 7 1 2 3 5 4 8 9 6 10 1 Label for crane identification 2 LED 3 Maneuver elements 4 Contact key 5 Start push button 6 STOP button 7 Optional Range limiter 8 External and extractable EEPROM module...

Page 7: ...achine and battery level only if it has been pre programmed crane xx1 LED pulse Display option 4 Press the start button The green LED will now light to indicate the transmitter is transmitting Once th...

Page 8: ...play the identification of the machine as well as the battery level if it has been pre programmed 4 Press the START button and wait for the status LED to turn to fixed green LED status green The statu...

Page 9: ...witches Removable EEPROM External Battery model BT27IK Battery life 8 hours Response Time 100ms Operating temperature range 20 C to 70 C 4 F to 158 F Storage Temperature Range 24h 25 C to 75 C 13 F to...

Page 10: ...w Color and frequency Pulse frequency Description Action Green continuous Working Operate Green slow pulses Latency no action has been taken for some time Press START to return to operation mode Red s...

Page 11: ...tion mode Red slow pulses EEPROM Error EEPROM module is missing or corrupted Check EEPROM module or reprogram if necessary Red double pulses Radio Error Radio communication error Replace transmitter R...

Page 12: ...15 Vca 60 Hz DC power supply From 10 5 V to 35 V BT27IK battery Specification Value Voltage 4 8 V Capacity 2700 mAh NiMH Charging temperature From 0 C to 45 C Discharge temperature From 20 C to 50 C A...

Page 13: ...cycles and is largely dependent on the conditions of use To maximize the lifespan of the batteries and battery charger follow these recommendations Do not recharge the battery until it is completely f...

Page 14: ...CB70 battery charger dimensions Dimensions in mm 131 60 179 80 128 50 40 34 50 User Manual Remote Control IK4 Transmitters Charger and battery 14 Danfoss May 2021 BC290863558440en 000201...

Page 15: ...Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New Distr...

Reviews: