background image

IK2 maintenance tips

This product is designed for use in an industrial environment that may shorten the product's lifespan. Use

these tips to maximize the lifespan of the product.

Use the hook/belt provided with the transmitter to prevent the transmitter from falling

Do not clean the transmitter with solvents or pressurized water; use a damp cloth or soft brush for

cleaning

If the push buttons show signs of deterioration, contact the Authorized Technical Service for repair

Check if the battery contacts are correct, otherwise replace them.

Ensure that the product is supplied with AAA alkaline batteries or has a rechargeable battery

Be sure to recharge or replace battery regularly

Maintenance tips quick reference

Troubleshooting (400-900 MHz)

The transmitter has status monitoring LED's which help identify irregularities. The most common signals

are contained in the table below:

Color and frequency

Pulse frequency

Description

Action

Green | continuous

Working

Operate

Green | slow pulses

Latency; no action has been taken for some time

Press START to return to operation

mode

Red | slow pulses

Low battery signal

Replace or recharge battery

Red | fast pulses

EEPROM module missing or corrupt

Check EEPROM and reprogram if

necessary

Red | double pulses

A maneuver is activated at transmitter start up process;

may indicate hardware damage if no order is active

Release maneuver or replace

transmitter if necessary

Red | continuous

General hardware failure

Replace transmitter

Troubleshooting 2.4GHz

Color and frequency

Pulse frequency

Description

Action

Blue | fast pulses

Starting the system; establishing communications with

radio and EEPROM

Wait

Blue | continuous

Stand-by mode. Set up system, waiting user's action

Press START to enter operation

mode

User Manual

Remote Control IK2 Transmitters

Maintenance

 

10 | 

©

 Danfoss | May 2021

BC290862531428en-000201

Summary of Contents for IK2

Page 1: ...User Manual Remote Controls IK2 Transmitters www danfoss com...

Page 2: ...revisions Date Changed Rev May 2021 Added trouble shooting and start up information for TR2400 0201 December 2018 Rebranded to Danfoss 0101 User Manual Remote Control IK2 Transmitters 2 Danfoss May 20...

Page 3: ...description 9 Maintenance Maintenance tips 10 Troubleshooting 400 900 MHz 10 Troubleshooting 2 4GHz 10 Charger and battery Charger and battery 12 BC70K and BT11K specifications 12 BC70K Battery Charg...

Page 4: ...llage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement IK2 General Safety The following saf...

Page 5: ...s press STOP before plugging in tether cable if applicable Remove the Tether connection on the transmitter First if applicable Do not operate product when visibility is limited Make sure product is co...

Page 6: ...1 2 3 5 8 9 10 1 Label for crane identification 2 LED 3 Maneuver elements 4 Multi key or Key START Button 5 STOP button 6 Optional range limiter 7 External and extractable EEPROM module 8 Battery 9 M...

Page 7: ...er has LCD it displays the identification of the machine and battery level only if it has been pre programmed crane xx1 LED pulse Display option 4 Press the start button The green LED will now light t...

Page 8: ...blue If the transmitter includes a Display it will display the identification of the machine as well as the battery level if it has been pre programmed 4 Press the START button and wait for the statu...

Page 9: ...switches Removable EEPROM External Battery model BT11K Battery life 8 hours Response Time 100ms Operating temperature range 20 C to 70 C 4 F to 158 F Storage Temperature Range 24h 25 C to 75 C 13 F to...

Page 10: ...ties The most common signals are contained in the table below Color and frequency Pulse frequency Description Action Green continuous Working Operate Green slow pulses Latency no action has been taken...

Page 11: ...n mode Red slow pulses EEPROM module missing or corrupt Check EEPROM and reprogram if necessary Red double pulses Radio error radio communications error Replace transmitter Red continuous General hard...

Page 12: ...perature 0 C to 45 C Discharge temperature 20 C to 60 C Charging mode Fast 2 5 h and intelligent Weight 23 g BC70K Battery Charger Set up The battery charger has two charging compartments that can sim...

Page 13: ...ies and battery charger follow these recommendations Do not recharge the battery until it is completely flat as shown with red LED slow pulse on the transmitter Always charge the batteries at temperat...

Page 14: ...BC70K Battery Charger Dimensions Dimensions mm 97 15 103 31 30 10 23 50 127 90 2 57 User Manual Remote Control IK2 Transmitters Charger and battery 14 Danfoss May 2021 BC290862531428en 000201...

Page 15: ...Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New Distr...