
A
B
C
D E
F
G
H
J K
L
M
N
P
Q
R
H1 B
A
Z
A
N N
N N N
Displacement
060
060 cm³ [3.66 in³]
080
080 cm³ [4.88 in³]
110
110 cm³ [6.71 in³]
160
160 cm³ [9.76 in³]
210
210 cm³ [12.81 in³]
250
250 cm³ [15.25 in³]
A – Product version
A
Revision code
Z – Port configuration
A
Inch, Customer O-ring port sealing according to ISO 11926-1
B – Control
Code
Control type
Voltage
PCOR
Displacement, supply
Connector
L1
Electric Proportional
12 V
—
De-energized = Maximum Displacement
DEUTSCH
DT04–2P
L2
24 V
—
D1
12 V
D2
24 V
M1
12 V
—
De-energized = Minimum Displacement
M2
24 V
—
K1
12 V
K2
24 V
E1
Electric 2-position
12 V
—
De-energized = Maximum Displacement
E2
24 V
—
F1
12 V
—
De-energized = Minimum Displacement
F2
24 V
—
T1
12 V
T2
24 V
P1
12 V
De-energized = Minimum Displacement,
with Electric Proportional PCOR
P2
24 V
DH
Hydraulic Proportional —
External pressure control supply,
Default (w/o control pressure) = Maximum
—
LH
—
MH
—
External pressure control supply
Default (w/o control pressure) = Minimum
KH
= available option, – = not available option
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Master Model Code
30 |
©
Danfoss | December 2016
11037153 | BC00000043en-US1103