Lifting lugs/eyes/points for lifting slings and lifting position of the electric machine
1 Lifting eye type of ANSI B18.15.1M M12x19 is recommended in M12 bores for horizontal and vertical lifting. Not
included in the delivery. Use the outmost lifting positions in horizontal lifting.
Horizontal lifting
Install 2 pieces of lifting eyes to the lifting bores in the electric machine frame. The lifting eyes should be
mounted with their full threaded length.
Vertical lifting
Install 4 pieces of lifting eyes to the lifting bores in the N-end bearing shield (non-shaft end). Lifting eye
should be mounted with its full threaded length.
Storage
Do not touch the electrical terminals when the shaft is rotated. The electrical terminals have
dangerous voltage during rotation.
Keep the electric machine on a correct base. Support the electric machine to prevent
accidental turning and falling.
User Guide
EM-PMI540-T2000
Transportation and storage
28 |
©
Danfoss | July 2021
BC265857530809en-000202