Different ambient air temperatures
•
Selected heat curve
•
Desired room temperature setting
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
-2 0
-1 8
-1 6
-1 4
-1 2
-1 0
- 8
- 6
- 4
- 2
0
2
4
6
8
10
12
14
16
18
20
22
24
26
48
50
44
46
42
36
38
40
34
32
30
28
26
24
22
20
18
16
14
12
1
2
3
4
Figure 5.
Heat curves and heat pump working range in AUTO mode
Position
Explanation
1
Initial supply line temperature (°C)
2
Supply line water temperature (°C)
3
Working range in AUTO mode
4
Outdoor Air temperature (°C)
Note! The reference point for the heat curves is an outside air temperature of -6°C.
When the outside air temperature is -6°C, selecting heat curve 45 and AUTO mode means that the heat pump will
adjust the water temperature to 45°C. Heat curve 45 is suitable for radiator heating.
16 – Installation and service instructions VMGFI202