Application

The thermostatic valve BVTS is designed for 

protection of biomass boilers and fire stoves. 

It prevents overheating of the boiler by 

discharging water from heat generator or 

condensing coil.

The valve is used also to prevent 

back-burning in the fuel store by flooding 

the fuel in case of excessive temperature.

Technical Data

Media:  

Water

Opening temperature:  

95 °C  ± 2 °C  

 

(fixed)

Max. sensor temperature:  125 °C 

Flow capacity:  

2.6 m

3

/h 

(∆p = 1bar) 

Connection size:  

G ¾ pipe thread  

 (ISO-228) 

Dimensions in [mm], (fig. 1)

Installation

Installation of BVTS valve on boiler with 

safety heat exchanger A (fig. 2). 

Installation of BVTS valve in back-burning 

application B (fig. 2) .

Before installation of the valve flush the 

system to make sure that there are no 

impurities which might deposit on the valve 

seat and cause malfunction.

Remember to install a filter ahead of the 

valve. (Fig. 3).

The sensor can be mounted in any position. 

Make sure the whole sensor is in contact 

with the controlled area. 

The arrow on the valve body shows 

direction of flow. When installing the valve, 

make sure it is positioned properly.

Max torque for sensor pocket mounting is 

30 Nm.

Only cooling applications:

After installation the proper function of the 

valve should be checked by heating up the 

system.

Service

It is recommended to check proper function 

of the valve once a year by qualified 

personnel. Functional check is carried out 

manually by depressing the red button that 

opens the flow on the valve.

It is not allowed to lose red button as it will 

cause product malfunction.

Tekniske data

Medier:  

Vand

Åbningstemperatur:  

95 °C ± 2 °C  (fast)

Maks. følertemperatur:   125 °C 

Flowkapacitet:   

2.6 m

3

/h  

(∆p = 1bar)

Tilslutningsstørrelse:  

G ¾ Rørgevind 

 (ISO-228) 

Dimensioner [mm], (fig. 1)

Installation

Installation af BVTS-ventilen på kedel med 

sikkerhedsvarmeveksler A (fig. 2).

Installation af BVTS-ventil som 

brandbeskyttelse B (fig. 2).

Før installation af ventilen skal systemet 

skylles igennem for at sikre, at der ikke 

findes urenheder, der kan aflejres på 

ventilsædet og forårsage fejlfunktion.

Husk at installere et filter foran ventilen. 

(Fig. 3).

Føleren kan installeres i en hvilken som 

helst position. Sørg for, at hele føleren er 

i kontakt med det kontrollerede område.

Pilen på ventilenheden viser flowets 

retning. Når ventilen installeres, skal sikres, 

at den er placeret korrekt. Maks. moment 

for føler lomme er 30Nm.

Kun køleformål:

Efter installation skal ventilens korrekte drift 

kontrolleres ved at varme systemet op.

Service

Det anbefales, at kvalificeret personale en 

gang om året kontrollerer ventilens korrek-

te drift. Funktionel kontrol udføres manuelt 

ved at trykke på den røde knap, som åbner 

flowet på ventilen.

Forskruningen der holder den røde test 

knap, må ikke løsnes, da dette vil medføre 

funktionsfejl.

ø16

B

A

Anvendelse

Den termostatiske ventil BVTS er konstrueret 

til beskyttelse af biomassekedler og 

brændeovne. Den forhindrer overhedning af 

kedlen ved at udlede vand fra varmege

neratoren eller kondensatorspolen.

Ventilen anvendes også til at undgå brand 

i brændstoflageret ved at oversprøjte 

brændstoffet med vand, hvis temperaturen 

bliver for høj.