AK-LM 330 Vers. 1.4x     

Menu operation   RC8CC202  ©  Danfoss  09/2012 

3

Note

It has been necessary to make a selection from the numerous measurements and settings coming 

from the controller.

There is not room for all these in the AKM programme controls.

It can display:

• 8 thermostats

• 2 pressostats

• 2 volt inputs

• 8 digital alarm inputs

• 2 consumption gauges

If it is necessary to obtain access to all measurements and settings, see Using Service Tool, type AK-ST 

500.

Go through the individual functions one by one and make the required settings. When settings have 

been made for one controller, the set values may be used as a basis in the other controllers of the 

same type and with the same software version. Copy the settings by using the copy settings function 

in the AKM programme, and adjust subsequently any settings where there are deviations. 

NB! If a list is required for noting down the individual settings, a printout can be made of it with 

a function in the AKM programme. Read the next section, “Documentation”.

Documentation

Documentation of the settings of the individual controllers can be made with the print function in the 

AKM programme. Select the controller for which documentation of the settings is required and select 

the “Print Settings” function (cf. also the AKM Manual).

Functions

Shown below are function groups with corresponding measurements and settings. A printout of the 

given settings can be made using the AKM function “Print Settings” (see above). 

Summary of Contents for AK-LM 330

Page 1: ...Monitoring unit AK LM 330 User Guide ADAP KOOL Refrigeration control systems...

Page 2: ...1 4 has been selected here From the measure line the different val ues can be read The values are constantly updated In the list of settings the set values can be seen If a setting has to be changed...

Page 3: ...ther controllers of the same type and with the same software version Copy the settings by using the copy settings function in the AKM programme and adjust subsequently any settings where there are dev...

Page 4: ...or OFF 2 3 4 There are similar settings for the other thermostats Settings Main switch Main switch ON Regulation OFF Controller stopped Th1 Cut out temp Cut out value for relay which is defined in The...

Page 5: ...been defined can be read here 1 to 2 can be read and operated in the following menus 3 or more can only be read and operated from the Service Tool AK ST 500 V1 value The voltage measurement for the f...

Page 6: ...the total number of changes to On The value can be reset DI1 Total ON time Readings for total On time The value can be reset 2 3 4 5 6 7 8 There are similar settings for the other DI inputs Utility m...

Page 7: ...be defined with setting 18 DI4 Alarm to be defined with setting 19 DI5 Alarm to be defined with setting 20 DI6 Alarm to be defined with setting 21 DI7 Alarm to be defined with setting 22 DI8 Alarm to...

Page 8: ...Overriding the alarms is defined with setting 0 Stand by mode Interrupted regulation See the above introduction Saux 1 error See the above introduction 2 3 4 5 6 7 8 As for Saux 1 Paux 1 error See the...

Reviews: