background image

© Danfoss | 2019.04

VI.LI.K1.02 | 1

ENGLISH

Flow Controller with integrated control valve AFQM 2, AFQMP 2

www.danfoss.com

Page 8

AFQM 2, AFQMP 2 (PN 16/25/40)

Operating Guide

AFQM 2 

PN 16/25/40
DN 65-125 + 

 AMV(E) 55/56

AFQM 2

PN 16/25/40

DN 65-250 + 

 AMV(E) 65x

AFQMP 2 

PN 16/25

DN 65-125 + 

 AMV(E) 55/56

AFQMP 2

PN 16/25

DN 65-250 + 

 AMV(E) 65x

AFQMP 2 / 

AMEi 6 iSET 

PN 16/25

DN 65-125 + 

 AMV(E) 55/56

AFQMP 2 / 

AMEi 6 iSET

PN 16/25

DN 65-250 + 

 AMV(E) 65x

AFQMP 2 PN16/25

DN 65-250

AFQM 2 PN16/25/40

DN 65-250

Summary of Contents for AFQM 2 PN16

Page 1: ...PN 16 25 40 Operating Guide AFQM 2 PN 16 25 40 DN 65 125 AMV E 55 56 AFQM 2 PN 16 25 40 DN 65 250 AMV E 65x AFQMP 2 PN 16 25 DN 65 125 AMV E 55 56 AFQMP 2 PN 16 25 DN 65 250 AMV E 65x AFQMP 2 AMEi 6 i...

Page 2: ...2 Danfoss 2019 04 VI LI K1 02 AFQM 2 AFQMP 2 AUTO 2 4 mm 5 95 RH no condensing MAINTENANCE FREE T 100 C T 100 C...

Page 3: ...Danfoss 2019 04 3 VI LI K1 02 AFQM 2 AFQMP 2 A AMV E 55 56 AMV E 55 65x B AMV E 65x AMV E 55 56 AMV E 65x...

Page 4: ...FQM 2 AFQMP 2 p 0 1 0 7 bar Type AFP 2 Code Nr 003G5650 p 1 3 bar Tmax 150 C Area cm2 80 Turn till end Hold Fix Release for turn Pull out SW46 Max 100 120 Nm 30 turns 2x SW36 SW36 Note setting can be...

Page 5: ...evolutions DN 100 p b 0 2 bar p b 0 5 bar 0 50 100 150 200 250 0 5 10 15 20 25 flow m 3 h No of revolutions DN 150 p b 0 2 bar p b 0 5 bar 0 50 100 150 200 250 300 350 0 5 10 15 20 25 30 flow m 3 h No...

Page 6: ...No of revolutions DN 100 p b 0 1 bar p b 0 7 bar 1 revolution 360 turns indicator 0 20 40 60 80 100 120 140 160 0 5 10 15 20 25 flow m 3 h No of revolutions DN 125 p b 0 1 bar p b 0 7 b a r 0 50 100 1...

Page 7: ...96 334 462 200 353 391 497 250 365 403 555 DN L H1 H2 H3 Valve weight kg mm PN 16 PN 25 PN40 65 290 355 505 540 49 51 56 80 310 355 515 540 58 60 67 100 350 390 540 570 91 93 105 125 400 395 575 610 1...

Page 8: ...ring and setting AMV E 65X 1 Install the actuator to the valve 2 Tighten the nuts to fix the ring 3 Connect stems 4 Tigten the connector again to connect the spindle of actuator and valve Read Instruc...

Page 9: ...d 4 The adjusting screw may be sealed drilling Adjustment with heat meter 1 Operate actuator manually or by control signal to retract the stem See the manual operation in instructions of AMV E 55 56 6...

Page 10: ...10 Danfoss 2019 04 VI LI K1 02 AFQM 2 AFQMP 2...

Page 11: ...Danfoss 2019 04 11 VI LI K1 02 AFQM 2 AFQMP 2...

Page 12: ...is also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material a...